A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionir4ehro10a05g58pko94r1jb4fopg2pn): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reverse-selective microporous membrane for gas separation. | LitMetric

Reverse-selective membranes, through which bigger molecules selectively permeate, are attractive for developing chemical processes utilizing hydrogen because they can maintain the high partial pressure of hydrogen required for their further downstream utilization. Although several of these chemical processes are operated above 473 K, membranes with outstanding reverse-selective separation performance at these temperatures are still to be reported. Herein, we propose a new adsorption-based reverse-selective membrane that utilizes a Na cation occluded in a zeolitic framework. The membrane developed in this work, a compact Na(+)-exchanged ZSM-5 (NaZSM-5) type zeolite membrane, enables us to selectively permeate and separate bigger polar molecules, such as methanol and water, from a stream containing hydrogen, above 473 K. On the other hand, a Na(+)-free, H(+)-exchanged ZSM-5 (HZSM-5) type zeolite membrane did not show separation properties at these temperatures. The microporous zeolite membrane developed in this study can be applied to a variety of chemical reaction systems to minimize energy consumption.

Download full-text PDF

Source
http://dx.doi.org/10.1002/asia.200900048DOI Listing

Publication Analysis

Top Keywords

zeolite membrane
12
selectively permeate
8
chemical processes
8
membrane developed
8
type zeolite
8
membrane
6
reverse-selective
4
reverse-selective microporous
4
microporous membrane
4
membrane gas
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!