We demonstrated a depth-resolved 3D imaging technique based on absorption contrast using tomosynthesis. Tomosynthesis is similar to computed tomography except that the number of projections is much smaller. We constructed a tomosynthesis imaging system, which detects a transmitted continuous THz wave. We applied a backprojection method that was suitable for the constructed detection configuration, to reconstruct an image. Using this system, we imaged a test sample made from paper and reproduced characters written by pencil.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/oe.17.009558 | DOI Listing |
Opt Express
June 2009
Yamagata University, Yonezawa, Yamagata, Japan.
We demonstrated a depth-resolved 3D imaging technique based on absorption contrast using tomosynthesis. Tomosynthesis is similar to computed tomography except that the number of projections is much smaller. We constructed a tomosynthesis imaging system, which detects a transmitted continuous THz wave.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!