Despite high efficacy of percutaneous coronary intervention (PCI), in-stent restenosis proves to be a significant problem of therapy. Restenosis concerns around 30 percent of patients. Studies have suggested that restenosis is initiated by cells which participate in intense inflammatory reaction caused by stent implantation. Atherosclerotic plaque rupture during stent implantation and PCI-associated injury of the vessel wall lead to hemorrhage and release of various cytokines. They are probably responsible for quick recurrence of vascular lumen stenosis (restenosis). Interleukin-6 (IL-6) is known as a main pro-inflammatory cytokine, whereas Transformig Growth Factor-beta1 (TGF-beta1) has anti-inflammatory properties. The study population comprised 36 patients with myocardial infarction treated with PCI with stent implantation. They underwent control coronary angiography after 12 months. At this time plasma concentration of IL-6 and TGF-beta was measured in peripheral blood. Serum IL-6 concentration in the analyzed population correlates with lumen loss (p<0.01) and the severity of stenosis (p<0.001). No such correlation was found between serum TGF-beta1 concentration and lumen loss (p=NS) or the severity of stenosis (p=NS). The IL-6 plasma concentration may be a marker of in-stent restenosis in patients after PTCA, while the concentration of TGF-beta1 is not associated with the occurrence of restenosis at one year of follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1177/039463200902200226DOI Listing

Publication Analysis

Top Keywords

stent implantation
12
growth factor-beta1
8
restenosis
5
role interleukin-6
4
interleukin-6 transforming
4
transforming growth
4
factor-beta1 predicting
4
predicting restenosis
4
restenosis stented
4
stented infarct-related
4

Similar Publications

Berlin Heart EXCOR sVAD implantation technique for neonates and infants with functionally univentricular ductal-dependent systemic circulation.

Multimed Man Cardiothorac Surg

January 2025

Congenital Heart Center, Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA.

The Berlin Heart EXCOR is a pulsatile paracorporeal ventricular assist device (VAD) for neonates, infants, children and adults with congenital or acquired severe ventricular dysfunction. Berlin Heart EXCOR VADs are routinely used as either a bridge to a cardiac transplantation, or occasionally as a bridge to ventricular recovery. Our programmatic philosophy is to bridge neonates and infants with functionally univentricular ductal-dependent systemic circulation or functionally univentricular ductal-dependent pulmonary circulation who are at high risk for staged palliation because of important cardiac risk factors with a single-ventricle VAD (sVAD) as a bridge to a cardiac transplant.

View Article and Find Full Text PDF

We describe a 12-year-old boy with agenesis of the intrahepatic segment of the inferior vena cava (a rare congenital anomaly) in whom an electrified coronary guidewire with electrocautery was used percutaneously to perforate and open the atretic segment, followed by stent implantation. This technique may be a safe and feasible option for paediatric patients, offering a therapeutic alternative for complex cardiac anatomies.

View Article and Find Full Text PDF

Background: He's team have recently developed a new Coronary Artery Tree description and Lesion EvaluaTion (CatLet) angiographic scoring system, which is capable of accounting for the variability in coronary anatomy, and risk-stratifying patients with coronary artery disease. Preliminary studies have demonstrated its superiority over the the Synergy between percutaneous coronary intervention with Taxus and Cardiac Surgery (SYNTAX) score with respect to outcome predictions for acute myocardial infarction (AMI) patients. However, there are fewer studies on the prognostic in chronic coronary artery disease(CAD).

View Article and Find Full Text PDF

Anti-inflammatory coupled anti-angiogenic airway stent effectively suppresses tracheal in-stents restenosis.

J Nanobiotechnology

January 2025

Department of Interventional Radiology, Key Laboratory of Interventional Radiology of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, China.

Excessive vascularization during tracheal in-stent restenosis (TISR) is a significant but frequently overlooked issue. We developed an anti-inflammatory coupled anti-angiogenic airway stent (PAGL) incorporating anlotinib hydrochloride and silver nanoparticles using advanced electrospinning technology. PAGL exhibited hydrophobic surface properties, exceptional mechanical strength, and appropriate drug-release kinetics.

View Article and Find Full Text PDF

Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.

Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!