Knee kinematics in medial osteoarthritis during in vivo weight-bearing activities.

J Orthop Res

Department of Mechanical and Aerospace Engineering, University of Florida, 318 MAE-A, Mail Stop 116250, Gainesville, Florida 32611-6250, USA.

Published: December 2009

Dynamic knee kinematics were analyzed for medial osteoarthritic (OA) knees in three activities, including two types of maximum knee flexion. Continuous x-ray images of kneeling, squatting, and stair climbing motions were taken using a large flat panel detector. CT-derived bone models were used for the model registration-based 3D kinematic measurements. Three-dimensional joint kinematics and contact locations were determined using two methods: bone-fixed coordinate systems and by interrogation of CT-based bone model surfaces. The femur exhibited gradual external rotation with knee flexion for kneeling and squatting activities, and gradual internal rotation with knee extension for stair climbing. From 100 degrees to 120 degrees flexion, contact locations showed a medial pivot pattern similar to normal knees. However, knees with medial OA displayed a femoral internal rotation bias and less posterior translation when compared with normal knees. A classic screw-home movement was not observed in OA knees near extension. Decreased variability with both activities and methods of calculation were demonstrated for all three activities. In conclusion, the weight-bearing kinematics of patients with medial OA differs from normal knees. Pathological changes of the articulating surfaces and the ligaments correspond to observed abnormalities in knee kinematics.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.20928DOI Listing

Publication Analysis

Top Keywords

knee kinematics
12
normal knees
12
three activities
8
knee flexion
8
kneeling squatting
8
stair climbing
8
contact locations
8
rotation knee
8
internal rotation
8
knee
6

Similar Publications

Background: The study focused on kinematically aligned total knee arthroplasty (KA TKA). It identified which coronal plane alignment of the knee (CPAK) types are associated with a higher proportion of medial deviation of the 6° prosthetic trochlear groove (PTG) relative to the quadriceps' line of pull and whether medial deviation adversely affected the Forgotten Joint Score (FJS). The research calculated the minimum PTG angle required to prevent medial deviation by at least 2° in all patients.

View Article and Find Full Text PDF

Background: The aim of this study was to assess whether there are any differences in plantar pressure distribution and gait cycle between patients with the same implant design and patients with different designs in staged bilateral TKA and to examine the impact of these differences on clinical and functional outcomes.

Methods: A retrospective review was conducted of all patients who underwent staged bilateral TKA. The patients were divided into two groups based on the prosthesis design used in both knees.

View Article and Find Full Text PDF

Meniscal forces and knee kinematics are affected by tibial slope modifying high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

January 2025

Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Purpose: To quantify the effect of increasing the posterior tibial slope (PTS) on knee kinematics and the resultant medial and lateral meniscal forces.

Methods: In this controlled laboratory study, a 6 degrees of freedom (DOF) robotic testing system was used to apply external loading conditions to seven fresh-frozen human cadaveric knees: (1) 200-N axial compressive load, (2) 5-N m internal tibial +10-N m valgus torque and (3) 5-N m external tibial + 10-N m varus torque. Knee kinematics and the resultant medial and lateral meniscal forces were acquired for two PTS states: (1) native PTS and (2) increased PTS.

View Article and Find Full Text PDF

In modern knee arthroplasty, surgeons increasingly aim for individualised implant selection based on data-driven decisions to improve patient satisfaction rates. The identification of an implant design that optimally fits to a patient's native kinematic patterns and functional requirements could provide a basis towards subject-specific phenotyping. The goal of this study was to achieve a first step towards identifying easily accessible and intuitive features that allow for discrimination between implant designs based on kinematic data.

View Article and Find Full Text PDF

Lower limb joint reaction forces during sit-to-stand and stand-to-sit movements in stroke patients with spastic hemiplegia.

J Electromyogr Kinesiol

January 2025

Research Academy of Grand Health, Faculty of Sports Sciences, Ningbo University, Ningbo, China. Electronic address:

Objective: We investigated the characteristics of hip, knee, and ankle joint reaction forces (JRFs) in stroke patients with spastic hemiplegia during sit-to-stand (Si-St) and stand-to-sit (St-Si) movements and explored the relationship between JRFs and joint moments.

Methods: Thirteen stroke patients with spastic hemiplegia and thirteen age-matched healthy subjects were recruited in this study. Three-dimensional motion capture system and force plates were employed to collect kinematic data and ground reaction forces during Si-St and St-Si tasks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!