We present a curve fitting method for measuring the spectral distribution of femtosecond laser pulses with Young's double-pair interference. The method is applicable to cancel the influence of the mutual coherent portion in the spectrum measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1364/opex.13.005689DOI Listing

Publication Analysis

Top Keywords

spectrum measurement
8
femtosecond laser
8
laser pulses
8
curve-fitting method
4
method pure
4
pure spectrum
4
measurement femtosecond
4
pulses pinhole
4
pinhole pair
4
pair curve
4

Similar Publications

Toward effective oxytocin interventions in autism: Overcoming challenges and harnessing opportunities.

J Psychopharmacol

January 2025

Neuromodulation Laboratory, Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium.

Intranasal administration of oxytocin is emerging as a potential pharmacological option for mitigating social difficulties and regulating stress in autism spectrum disorder. However, initial single-dose and multiple-dose trials showed mixed results, with some demonstrating improvements in social and repetitive behavior and others showing no benefit over placebo. This perspective aims to elucidate factors contributing to this variability and to highlight pitfalls and opportunities in the field.

View Article and Find Full Text PDF

Dengue fever, caused by the dengue virus (DENV), poses a significant global health challenge, particularly in tropical and subtropical regions. Recent increases in indigenous DENV cases in Europe are concerning, reflecting rising incidence linked to climate change and the spread of mosquitoes. These vectors thrive under environmental conditions like temperature and humidity, which are increasingly influenced by climate change.

View Article and Find Full Text PDF

Background: The metabolism of plasma amino acid (AA) in children with autism spectrum disorder (ASD) has been extensively investigated, yielding inconclusive results. This study aims to characterize the metabolic alterations in AA profiles among early-diagnosed children with ASD and compare the findings with those from non-ASD children.

Methods: We analyzed plasma AA profiles, measured by ion exchange chromatography, from 1242 ASD children (median age = 4 years; 81% male).

View Article and Find Full Text PDF

Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography.

Pharmaceuticals (Basel)

December 2024

Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307 Dresden, Germany.

(1) : Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of Pb- and Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the Pb/Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) : The routine alpha detection on thin-layer chromatograms (TLC) of Pb- and Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) : For Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken.

View Article and Find Full Text PDF

Integrated Spectral Sensitivity as Physics-Based Figure of Merit for Spectral Transducers in Optical Sensing.

Sensors (Basel)

January 2025

Department of Applied Physics and Science Education, Eindhoven Hendrik Casimir Institute, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands.

The design of optical sensors aims at providing, among other things, the highest precision in the determination of the target measurand. Many sensor systems rely on a spectral transducer to map changes in the measurand into spectral shifts of a resonance peak in the reflection or transmission spectrum, which is measured by a readout device (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!