Purpose: To compare the torsional strengths and the effects of functional loading on five different implant surface structures.
Materials And Methods: This in vivo longitudinal study of 9 months' duration examined osseointegration in 180 stepped cylindric implants placed into the mandibles of 18 healthy sheepdogs. Implants with five different surface structures were placed (n = 36 in each group): (1) smooth surface; (2) deep profile structure (DPS); (3) titanium plasma sprayed (TPS); (4) hydroxyapatite coated; and (5) sol-gel hydroxyapatite coated (SGHA). All implants were investigated under standardized conditions. At uncovering (3 months), half the implants were loaded with prefabricated crowns for 6 months, and the other half remained unloaded. Removal torque values were evaluated at 3, 6, and 9 months after implant placement. The data were analyzed using analysis of variance and Scheffé correction (alpha < .05).
Results: All smooth-surface and SGHA implants failed in succession during the fourth and ninth months of the study. After 3 months the removal torque resistance of DPS, TPS, and hydroxyapatite-coated implants was significantly higher (P < .001) than that seen in the other two groups. Initially, the removal torque resistance of unloaded hydroxyapatite-coated implants was superior, and the decrease during the observation period was not significant. The increase in removal torque resistance under functional loading was not significant for the DPS implants. A significant increase was found in removal torque resistance for the loaded TPS implants (P < .05). The unloaded DPS and TPS implants showed no change in removal torque levels after the closed healing period of 3 months.
Conclusions: Successful osseointegration was achieved with DPS, TPS, and hydroxyapatite-coated implants, and smooth-surface and SGHA implants failed. Removal torque resistance was enhanced with controlled functional loading.
Download full-text PDF |
Source |
---|
J Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
Int J Spine Surg
December 2024
Department of Scientific Affairs, Globus Medical, Inc., Audubon, PA, USA.
Background: Anterior column realignment is an attractive minimally invasive treatment for sagittal imbalance. Expandable spacers offer controlled tensioning of the anterior longitudinal ligament (ALL) during release, which could optimize correction and anterior column stability. This study investigated the biomechanical and radiographic effects of single-level anterior-to-psoas lumbar interbody fusion (ATP-LIF) with expandable spacers and sequential ALL release.
View Article and Find Full Text PDFJ Prosthet Dent
November 2024
Associate Professor, State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Implant Dentistry, School of Stomatology, The Air Force Medical University, Xi'an, PR China. Electronic address:
Statement Of Problem: Three months after implant placement, difficulty was encountered in unscrewing the healing abutment within the normal torque range (<35 Ncm), resulting in the removal of the implant. Despite all attempts, the implant could not then be separated from the healing abutment. Retrospective analysis of intraoperative photographs revealed the presence of blood or bone debris within the implant before the healing abutment was placed; this was considered to be the likely cause of this phenomenon.
View Article and Find Full Text PDFJ Funct Biomater
November 2024
Department of Basic Sciences, Araçatuba School of Dentistry, São Paulo State University "Júlio de Mesquita Filho", Araçatuba 16018-805, São Paulo, Brazil.
Estrogen deficiency is one of several contributing factors to catabolic changes in bone surrounding dental implants, impairing bone repair in defects requiring bone regeneration. Functionalizing bone substitutes is an alternative approach among various strategies to address this challenge. In this study, the aim was to evaluate the effect of functionalizing deproteinized bovine bone (Bio-Oss, BO) with genistein via sonication on peri-implant bone defects in ovariectomized rats.
View Article and Find Full Text PDFOrthop J Sports Med
November 2024
Department of Orthopaedic Surgery, Stanford University, Stanford, California, USA.
Background: Acetabular labral tear morphology or orientation may influence hip stability.
Hypothesis: A radial tear of the acetabular labrum would result in greater rotational and translational motion compared with a chondrolabral separation.
Study Design: Controlled laboratory study.