AI Article Synopsis

  • This study compared the need for Nd:YAG laser treatment among three types of square-edged intraocular lenses (IOLs) after cataract surgery.
  • The analysis involved 767 eyes of patients aged 50-85 and looked at two hydrophobic lenses (SA60AT and AR40E) and one hydrophilic lens (XL-Stabi).
  • Results showed that the SA60AT lens had the lowest rate of patients requiring Nd:YAG laser treatment after 3 years, significantly lower compared to the other two lenses.

Article Abstract

Objective: To compare the incidence of Nd:YAG laser treatment following 3 square-edged intraocular lenses (IOLs) of different composition implanted during cataract surgery.

Design: Patient chart analysis.

Participants: Patients aged 50-85 years and given a hydrophobic acrylic IOL (either SA60AT or AR40E) or hydrophilic acrylic IOL (XL-Stabi) were included. Analysis was conducted of 767 eyes treated with SA60AT (n = 250), AR40E (n = 254), or XL-Stabi (n = 263).

Methods: This retrospective study involved patients who had undergone cataract surgery between 2001 and 2002. Ophthalmology centres were accepted into the study if they used at least 2 of the IOLs being investigated. The medical files of patients fulfilling the inclusion criteria were listed, and eligible cases were selected randomly. Patients' characteristics were obtained from their medical files. Data on postsurgical complications and Nd:YAG laser treatment over 3 years were also extracted. Follow-up data were obtained from the medical files and the patients' ophthalmologists. Time to Nd:YAG laser treatment was analysed using Kaplan-Meier survival curves adjusted with a Cox model.

Results: After 3 years' follow-up the proportions of patients who had not received Nd:YAG laser treatment were 87.0% with SA60AT, 76.6% with AR40E, and 54.6% with XL-Stabi (p < 0.001). Cox's model adjusted for centre effects and the presence of diabetes estimated risk ratios of 2.8 for AR40E (p < 0.0005) and 5.1 for XL-Stabi (p < 0.0001), compared with the reference lens SA60AT.

Conclusions: Of the 3 square-edged lenses studied, the SA60AT was associated with a lower incidence of Nd:YAG laser treatment than either AR40E or XL-Stabi.

Download full-text PDF

Source
http://dx.doi.org/10.3129/i09-007DOI Listing

Publication Analysis

Top Keywords

ndyag laser
24
laser treatment
20
incidence ndyag
12
medical files
12
cataract surgery
8
square-edged lenses
8
acrylic iol
8
laser
6
ndyag
5
treatment
5

Similar Publications

Treatment of onychomycosis includes topical and systemic agents. However, prolonged use of oral treatment could cause adverse effects and topical antifungal agents have limited penetration. To compare the clinical efficacy and the safety of fractional CO laser combined with topical tioconazole nail solution versus Q-switched 1064 Nd: YAG laser in the treatment of fingernail onychomycosis.

View Article and Find Full Text PDF
Article Synopsis
  • Melasma is a common, chronic skin condition that mainly affects women, presenting as dark patches on the face and is often perceived as a serious cosmetic issue.
  • A survey conducted among 199 dermatologists in Turkiye revealed that the majority of patients with melasma are females between the ages of 30 to 40, with mixed melasma being the most common type.
  • The study found that topical treatments, particularly Kligman's formula, are most frequently used, while oral treatments like tranexamic acid are less common, and there's a significant recurrence rate of 41%-60%, suggesting the need for better management strategies.
View Article and Find Full Text PDF

Anion photoelectron spectra of ThSO- and ThS2- were recorded using the third (355 nm) harmonic of an Nd-YAG laser; these provided the measured vertical detachment energies of each anion. The experiments are supported by extensive coupled cluster calculations on ThSO, ThSO-, ThS2, and ThS2-, as well as the oxygen congeners ThO2 and ThO2-. The ab initio calculations, which included complete basis set extrapolations, spin-orbit effects using four-component coupled cluster, and higher-order correlation contributions through CCSDT(Q), yielded an adiabatic electron affinity for ThO2 that was within 0.

View Article and Find Full Text PDF

Plasma focus devices represent a class of hot and dense plasma sources that serve a dual role in fundamental plasma research and practical applications. These devices allow the observation of various phenomena, including the z-pinch effect, nuclear fusion reactions, plasma filaments, bursts, shocks, jets, X-rays, neutron pulses, ions, and electron beams. In recent years, considerable efforts have been directed toward miniaturizing plasma focus devices, driven by the pursuit of both basic studies and technological advancements.

View Article and Find Full Text PDF
Article Synopsis
  • The study looked at the risks of retinal detachment (RD) after a specific eye surgery called Boston Type 1 Keratoprosthesis (B1KPro) during the first year and beyond.
  • They found that 29% of patients experienced RD, with most cases happening within the first year (21%) and fewer later (7%).
  • Important risk factors for early RD included low eye pressure (hypotony), previous eye surgeries, and certain eye conditions, while changes in the retina before surgery were linked to later RD.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!