A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simulation of surgical glenoid resurfacing using three-dimensional computed tomography of the arthritic glenohumeral joint: the amount of glenoid retroversion that can be corrected. | LitMetric

Hypothesis: The magnitude of glenoid retroversion that can be surgically corrected in total shoulder arthroplasty and still enable implantation of a glenoid component has not been established. We hypothesized that increased retroversion will require smaller glenoid components for successful implantation when the glenoid is surgically corrected and that correction beyond 20 degrees of retroversion is not feasible without peg penetration.

Methods: Using 3-dimensional models created from computed tomography of 19 patients with advanced shoulder osteoarthritis, we simulated glenoid resurfacing on varying degrees of retroverted, osteoarthritic glenoids using an in-line 3-peg glenoid component and asymmetric reaming to correct version.

Results: Glenoids with preoperative retroversion of less than 12 degrees could always be implanted with 46-mm and 52-mm glenoid components at neutral version without vault violation. Conversely, glenoids with greater than 18 degrees of preoperative retroversion could not be implanted at neutral version due to vault violation from the pegs. The average preoperative glenoid retroversion of patients in which a 46-mm glenoid was implanted at neutral version was 8.9 degrees +/- 6.4 degrees compared with 19.0 degrees +/- 7.1 degrees for those that could not be implanted at neutral (P = .005).

Discussion: Computer-aided surgical simulation shows that glenoid retroversion is a critical factor in determining successful glenoid implantation. Smaller sized glenoid components allow for greater version correction and less residual postsimulation retroversion when an in-line pegged component is used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2009.03.019DOI Listing

Publication Analysis

Top Keywords

glenoid retroversion
16
glenoid
14
glenoid components
12
neutral version
12
implanted neutral
12
retroversion
9
glenoid resurfacing
8
computed tomography
8
surgically corrected
8
implantation glenoid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!