Knee strength capabilities and slip severity.

J Appl Biomech

Human Movement and Balance Laboratory, Department of Bioengineering, Pittsburgh, PA, USA.

Published: May 2009

Slips and falls are a serious public health concern in older populations. Reduced muscle strength is associated with increased age and fall incidence. Understanding the relationships between specific joint muscle strength characteristics and propensity to slip is important to identify biomechanical factors responsible for slip-initiated falls and to improve slip/fall prevention programs. Knee corrective moments generated during slipping assist in balance recovery. Therefore, the study goal was to investigate the relationship between knee flexion/extension strength and slip severity. Isometric knee flexion/extension peak torque and rate of torque development (RTD) of the slipping leg were measured in 29 young and 28 older healthy subjects. Motion data were collected for an unexpected slip during self-paced walking. Peak slip velocity (PSV) of the slipping heel served as a slip severity measure. Within-sex and age group regressions relating gait speed-controlled PSV to strength of the slipping leg revealed significant inverse PSV-knee extension peak torque and PSV-knee flexion/extension RTD relationships in young males only. Differences in PSV-strength relationships between sex and age groups may be caused by greater ranges of strength capabilities in young males. In conclusion, the ability to generate higher, more rapid knee flexion/ extension muscle moments (greater peak torque/RTD) may assist in recovery from severe slips.

Download full-text PDF

Source
http://dx.doi.org/10.1123/jab.25.2.140DOI Listing

Publication Analysis

Top Keywords

slip severity
12
strength capabilities
8
muscle strength
8
knee flexion/extension
8
peak torque
8
slipping leg
8
young males
8
slip
6
knee
5
strength
5

Similar Publications

Objective: High-grade dysplastic spondylolisthesis (HGDS) is a relatively rare condition mainly involving the L5/S1 segment of the spine and occurring in children and adolescents. Whether surgical fixation should be L5-S1 monosegmental or extended up to L4 remains controversial. This study aimed to compare clinical outcomes and the risk of adjacent segment spondylolisthesis between L5-S1 monosegmental fixation and L4-S1 double-segmental fixation for pediatric HGDS.

View Article and Find Full Text PDF

Objective: To explore the correlation between vitamin D levels, related endocrine/metabolic factors, and the risk of slipped capital femoral epiphysis (SCFE) in children and adolescents, and to assess whether vitamin D levels are associated with SCFE severity.

Methods: A retrospective case-control study was conducted from March 2014 to October 2023 in Shengjing hospital. Patients diagnosed with SCFE were categorized as the SCFE group.

View Article and Find Full Text PDF

Excess cement and peri-implant disease: A cross-sectional clinical endoscopic study.

J Periodontol

January 2025

Department of Biomedical and Neuromotor Sciences, School of Dentistry - Division of Periodontology and Implantology, Alma Mater Studiorum - University of Bologna, Bologna, Italy.

Background: Crown cementation is a common technique for implant-supported prosthodontics. However, for possible slipping of the cement below the mucosal margin, its thorough removal poses some issues. The objective of this study was to evaluate the presence of submucosal cement residues in patients with peri-implant disease by endoscopic visualization and to investigate the potential correlation between the pathological scenario and the spatial position of cement residues.

View Article and Find Full Text PDF

Strong, ductile, and hierarchical hetero-lamellar-structured alloys through microstructural inheritance and refinement.

Proc Natl Acad Sci U S A

January 2025

Department of Materials Science and Engineering, Hong Kong Institute for Advanced Study, City University of Hong Kong, Hong Kong, China.

The strength-ductility trade-off exists ubiquitously, especially in brittle intermetallic-containing multiple principal element alloys (MPEAs), where the intermetallic phases often induce premature failure leading to severe ductility reduction. Hierarchical heterogeneities represent a promising microstructural solution to achieve simultaneous strength-ductility enhancement. However, it remains fundamentally challenging to tailor hierarchical heterostructures using conventional methods, which often rely on costly and time-consuming processing.

View Article and Find Full Text PDF

Due to limited slip systems activated at room temperature, the plastic deformation of Mg and its alloys without any preheating of initial billets is significantly limited. To overcome those issues, new methods of severe plastic deformation are discovered and developed. One such example is extrusion with an oscillating die, called KoBo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!