Background: There is considerable interest in developing coitally independent, sustained release formulations for long-term administration of HIV microbicides. Vaginal ring devices are at the forefront of this formulation strategy.
Methods: Non-medicated silicone elastomer vaginal rings were prepared having a range of appropriate dimensions for testing vaginal fit in pig-tailed and Chinese rhesus macaques. Cervicovaginal proinflammatory markers were evaluated. Compression testing was performed to compare the relative flexibility of various macaque and commercial human rings.
Results: All rings remained in place during the study period and no tissue irritation or significant induction of cervicovaginal proinflammatory markers or signs of physical discomfort were observed during the 8-week study period.
Conclusions: Qualitative evaluation suggests that the 25 x 5-mm ring provided optimal fit in both macaque species. Based on the results presented here, low-consistency silicone elastomers do not cause irritation in macaques and are proposed as suitable materials for the manufacture of microbicide-loaded vaginal rings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1600-0684.2009.00354.x | DOI Listing |
BMJ Sex Reprod Health
December 2024
Research Department of Reproductive Health, University College London (UCL) EGA Institute for Women's Health, London, UK.
PLoS One
January 2025
US Department of Veterans Affairs, Palo Alto Healthcare System, National Center for Collaborative Healthcare Innovation, Palo Alto, California, United States of America.
Background: The intrauterine device (IUD) is a highly effective form of long-acting reversible contraception, widely recognized for its convenience and efficacy. Despite its benefits, many patients report moderate to severe pain during and after their IUD insertion procedure. Furthermore, reports suggest significant variability in pain control medications, including no adequate pain medication.
View Article and Find Full Text PDFFront Pharmacol
December 2024
Pharmacy Department, Xiamen Fifth Hospital, Xiamen, Fujian, China.
Background: This study aims to investigate adverse drug reaction signals associated with coagulopathies through data mining using the Adverse Event Reporting System (FAERS) of the US Food and Drug Administration. Prompt identification of high-risk drugs provides a valuable basis for enhancing clinical drug safety.
Methods: The adverse event reports related to coagulopathies from Q1 2004 to Q2 2024 were extracted from the ASCII data packages in FAERS.
BMC Womens Health
December 2024
Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.
Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.
View Article and Find Full Text PDFRev Bras Ortop (Sao Paulo)
November 2024
Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil.
During the gestational period, the pubic symphysis dilates for vaginal delivery. However, exacerbated widening may indicate ligament injury and pelvic instability, resulting in significant pain complaints. This uncommon condition is called peripartum pubic symphysis disjunction (PPSD).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!