We have developed a field-worthy, high-definition, real-time depth-mapping television camera called the HDTV Axi-Vision Camera. The camera can simultaneously capture both an ordinary HDTV color image and a depth image of objects on more than 1280 x 720 pixels at a frame rate of 29.97 Hz, or on 853 x 480 pixels at a frame rate of 59.94 Hz. The number of detectable pixels per unit time was increased by about 5 times that of the prototype camera by improving the sensitivity and resolution of the depthmapping camera. Short video clips demonstrate how depth information from the camera can be used to create a virtual image in actual television program production.

Download full-text PDF

Source
http://dx.doi.org/10.1364/opex.12.002781DOI Listing

Publication Analysis

Top Keywords

high-definition real-time
8
real-time depth-mapping
8
camera
8
hdtv axi-vision
8
axi-vision camera
8
pixels frame
8
frame rate
8
depth-mapping camera
4
camera hdtv
4
camera developed
4

Similar Publications

Background: Endoscopic assessment for the diagnosis of gastric cancer is limited by interoperator variability and lack of real-time capability. Recently, Raman spectroscopy-based artificial intelligence (AI) has been proposed as a solution to overcome these limitations.

Objective: To compare the performance of the AI-enabled Raman spectroscopy with that of high-definition white light endoscopy (HD-WLE) for the risk classification of gastric lesions.

View Article and Find Full Text PDF

High-Definition, Video-Rate Triple-Channel NIR-II Imaging Using Shadowless Lamp Excitation and Illumination.

ACS Nano

January 2025

State Key Laboratory of Extreme Photonics and Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China.

Multichannel imaging in the second near-infrared (NIR-II) window offers vital and comprehensive information for complex surgical environments, yet a simple, high-quality, video-rate multichannel imaging method with low safety risk remains to be proposed. Centered at the superior NIR-IIx window of 1400-1500 nm, triple-channel imaging coordinated with 1000-1100 and 1700-1880 nm (NIR-IIc) achieves exceptional clarity and an impressive signal-to-crosstalk ratio as high as 22.10.

View Article and Find Full Text PDF

Historically, blind intrauterine procedures such as dilation and curettage (D&C) and blind endometrial biopsies have been the primary approach for diagnosing and managing intrauterine pathologies. However, these techniques lack direct visualization, leading to diagnostic limitations, incomplete treatment, and increased complication rates. Despite substantial advances in hysteroscopic technology, including high-definition imaging and minimally invasive instruments, blind procedures remain widely used.

View Article and Find Full Text PDF

Imaging colonic polyps in 2024.

Indian J Gastroenterol

October 2024

Department of Gastroenterology, Hepatology and Clinical Nutrition, Aster CMI Hospital, Bengaluru, 560 092, India.

Article Synopsis
  • Screening colonoscopy and polypectomy are essential for reducing colorectal cancer rates, especially as India's incidence of colonic polyps and cancer has been increasing despite overall low rates.
  • Proper training for healthcare providers in detecting and characterizing polyps is crucial, using techniques like high-definition endoscopy and image-enhanced tools to improve outcomes.
  • Advancements in GI endoscopy technology, including artificial intelligence and newer imaging methods, are promising and indicate a need for ongoing education in polyp management and prediction of advanced pathology.
View Article and Find Full Text PDF
Article Synopsis
  • A new method for detecting cracks in underground sewage pipelines utilizes pipeline robots and an enhanced version of the YOLOv8n algorithm to effectively identify issues in both water and sludge environments.
  • The implementation of the lightweight RGCSPELAN module and adjustments to the detection head improve feature extraction while reducing the model's parameters to just 1.6 million, which enhances efficiency in real-time detection.
  • The results from real-world applications demonstrate that this method is effective at identifying both small and large cracks, potentially improving the safety, detection efficiency, and cost-effectiveness of urban sewage maintenance.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!