Modern cementing techniques aim to improve the interlock between bone and cement and to establish a durable interface. Cement penetration is generally believed to influence interface failure, but current methods for improving the cement-bone interface are inadequate. Oscillation is the reciprocated movement of an object through its balanced position, or the quantum physics of systematic fluctuation back and forth near an average value (or trimmed value). To increase the interlock strength at the cement-bone interface, we designed a cement oscillator according to the principles of vibrational mechanics. To evaluate the effect of oscillation on the quality of interlock strength at the cement-bone interface, we randomly divided 156 femoral bones of adult pigs into 2 groups, oscillated and control, and performed mechanical tests to assess interlock strength at the cement-bone interface. The filling effect of bone cement was observed and analyzed under a stereomicroscope, and then each oscillated femur was compared with a control femur. The interlock strength at the cement-bone interface in the oscillated group was significantly greater than in the control group (P<.05), and the filling effect in the oscillated group was also better than that in the control group (P<.05). Our findings show that oscillation of bone cement significantly increases interlock strength at the cement-bone interface, point the way for clinicians to develop a high-performance and pragmatic fixation technique for prostheses to increase interlock strength, and will be of considerable practical importance in helping to prevent aseptic loosening of cemented prostheses.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cement-bone interface
24
interlock strength
20
strength cement-bone
20
interface
8
bone cement
8
interlock
6
cement-bone
6
cement
5
strength
5
cement oscillation
4

Similar Publications

Glenoid implants used in anatomic total shoulder arthroplasties typically incorporate peripheral pegs as a design feature to support eccentric loads. These peripheral pegs and the implant-cement-bone interface undergo substantial cyclic tensile-compressive loads during normal activity. Therefore, these pegs are of interest in translating the micromechanics of local implant fixation failure to the biomechanics of gross anatomic failure of the glenoid implant after total shoulder arthroplasty.

View Article and Find Full Text PDF

Progressive osteolysis can occur at the cement-bone interface of joint replacements and the associated loss of fixation can lead to clinical loosening. We previously developed a rat hemiarthroplasty model that exhibited progressive loss of fixation with the development of cement-bone gaps under the tibial tray that mimicked patterns found in human arthroplasty retrievals. Here we explored the ability of a bisphosphonate (zoledronic acid, ZA) to attenuate cement-bone osteolysis and maintain implant stability.

View Article and Find Full Text PDF
Article Synopsis
  • Conventional radiography is commonly used to check for complications after total hip arthroplasty, but recent discussions have shown it is mainly helpful to rule out other issues rather than directly confirm infections.
  • There is limited data on how periprosthetic joint infections (PJI) appear on radiographs, making it difficult to determine the diagnostic value of these images, especially in low-grade infections.
  • The review highlights typical radiologic signs of PJI (like periosteal reactions and implant loosening) and calls for more research to understand these features better, aiming to improve diagnosis in the future.
View Article and Find Full Text PDF

Valgus instability can occur after total knee arthroplasty (TKA) due to traumatic medial collateral ligament (MCL) injury, component malpositioning, or progressive ligamentous laxity. Although revision TKA with exchange of the polyethylene to a varus-valgus-constrained liner can reduce laxity due to MCL insufficiency, isolated liner exchange in the setting of collateral ligament insufficiency may lead to greater strain at the cement-bone or implant-cement interface and possibly a greater rate of aseptic loosening. Anatomic MCL reconstruction can be performed in conjunction with liner exchange to restore stability and reduce strain compared with liner exchange alone.

View Article and Find Full Text PDF

Background And Objectives: Optimal iliac screw position in relation to the sciatic notch remains unknown. In 12 cadavers undergoing S2 alar-iliac (S2AI) screw placement, we tested the pullout strength of screws placed in proximity to the sciatic notch (≤5 mm) vs farther away from the sciatic notch (>5 mm).

Methods: A biomechanical, cadaver-based study was performed on 12 cadavers undergoing bilateral S2AI screw insertion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!