A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Percutaneous mitral annuloplasty device leaves free access to cardiac veins for resynchronization therapy. | LitMetric

Objectives: To assess the feasibility to place a left ventricular lead into the coronary sinus following percutaneous mitral annuloplasty.

Background: Percutaneous coronary sinus-based mitral annuloplasty may reduce functional mitral regurgitation in chronic systolic heart failure. However, concerns have been raised whether the placement of an annular remodeling device in the coronary sinus might preclude subsequent lead placement for resynchronization therapy (CRT).

Methods: Three patients with ischemic cardiomyopathy included in the AMADEUS trial underwent CRT 7 to 8 months after implantation of a mitral valve annuloplasty device.

Results: Fluoroscopy and control coronary angiography revealed a stable position of the annuloplasty device without any compromise of coronary blood flow. Intravascular ultrasound of the coronary sinus excluded any thrombus formation and demonstrated smooth endothelialization of the annular remodeling device. Access of the coronary sinus and placement of the left ventricular lead into a posterolateral cardiac vein was not at all compromised by the mitral valve annuloplasty device in any patient.

Conclusions: Positioning a left ventricular pacing lead for CRT is feasible after permanent implantation of a coronary sinus-based mitral annuloplasty device in patients with dilated cardiomyopathy.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.22097DOI Listing

Publication Analysis

Top Keywords

annuloplasty device
16
coronary sinus
16
mitral annuloplasty
12
left ventricular
12
percutaneous mitral
8
resynchronization therapy
8
ventricular lead
8
coronary
8
coronary sinus-based
8
sinus-based mitral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!