This study evaluates the accuracy of augmenting initial intraprocedural computed tomography (CT) during radiofrequency ablation (RFA) of hepatic metastases with preprocedural positron emission tomography (PET) through a hardware-accelerated implementation of an automatic nonrigid PET-CT registration algorithm. The feasibility of augmenting intraprocedural CT with preprocedural PET to improve localization of CT-invisible but PET-positive tumors with images from actual RFA was explored. Preprocedural PET and intraprocedural CT images from 18 cases of hepatic RFA were included. All PET images in the study originated from a hybrid PET/CT scanner, and PET-CT registration was performed in two ways: (1) direct registration of preprocedural PET with intraprocedural CT and (2) indirect registration of preprocedural CT (i.e., the CT of hybrid PET/CT scan) with intraprocedural CT. A hardware-accelerated registration took approximately 2 min. Calculated registration errors were 7.0 and 8.4 mm for the direct and indirect methods, respectively. Overall, the direct registration was found to be statistically not distinct from that performed by a group of clinical experts. The accuracy, execution speed, and compactness of our implementation of nonrigid image registration suggest that existing PET can be overlaid on intraprocedural CT, promising a novel, technically feasible, and clinically viable approach for PET augmentation of CT guidance of RFA.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3046698 | PMC |
http://dx.doi.org/10.1007/s10278-009-9204-x | DOI Listing |
Indian J Thorac Cardiovasc Surg
February 2025
Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka India.
Autoimmune hemolytic anemia (AIHA) secondary to mediastinal teratoma is a very rare clinical entity. They can be primary or secondary to any infections, malignancy, etc. Yet at times, there could be a delay in the diagnosis.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
January 2025
Department of Interventional Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL, USA.
Purpose: A single-center retrospective study was performed to evaluate the safety and efficacy of minimally invasive irreversible electroporation (IRE) to treat metastatic adrenal tumors.
Materials And Methods: This single-center study, approved by the Institutional Review Board, retrospectively analyzed six patients who underwent image-guided percutaneous IRE for adrenal metastases. Pre-procedural imaging included CT, MRI and/or F-FDG PET-CT scans.
J Nucl Cardiol
November 2024
Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, USA; Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, USA; Department of Biomedical Engineering, Yale University, New Haven, CT, USA. Electronic address:
Lower extremity peripheral artery disease (PAD) is characterized by impairment of blood flow associated with arterial stenosis and frequently coexisting microvascular disease and is associated with high rates of morbidity and mortality. Current diagnostic modalities have limited accuracy in early diagnosis, risk stratification, preprocedural assessment, and evaluation of therapy and are focused on the detection of obstructive atherosclerotic disease. Early diagnosis and assessment of both large vessels and microcirculation may improve risk stratification and guide therapeutic interventions.
View Article and Find Full Text PDFPhys Med Biol
August 2024
Department of Radiology, University of California, Davis, Sacramento, CA, United States of America.
Contrast-enhanced computed tomography (CECT) is commonly used in the pre-treatment evaluation of liver Y-90 radioembolization feasibility. CECT provides detailed imaging of the liver and surrounding structures, allowing healthcare providers to assess the size, location, and characteristics of liver tumors prior to the treatment. Here we propose a method for translating CECT images to an expected dose distribution for tumor(s) and normal liver tissue.
View Article and Find Full Text PDFPurpose This study aims to assess the significance of imaging techniques and needle thickness employed in transthoracic core needle biopsy for determining the cancer type and subtypes, ultimately guiding the treatment of lung cancer. Material and methods Between 2018 and 2023, a cohort of 350 patients (69.7% male, 30.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!