The first observation of parametric down-conversion in silicon is reported. Conversion from 1542.3nm to 1328.8nm is achieved using a CW pump laser at 1427 nm. The conversion occurs via Coherent Anti-Stokes Raman Scattering (CARS) in which two pump photons and one Stokes photon couple through a zone-center optical phonon to an anti-Stokes photon. The maximum measured Stokes/anti-Stokes power conversion efficiency is 1x10-5. The value depends on the effective pump power, the Stimulated Raman Scattering (SRS) coefficient of bulk silicon, and waveguide dispersion. It is shown that the power conversion efficiency is a strong function of phase mismatch inside the waveguide.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.11.002862DOI Listing

Publication Analysis

Top Keywords

anti-stokes raman
8
raman scattering
8
power conversion
8
conversion efficiency
8
conversion
5
raman conversion
4
conversion silicon
4
silicon waveguides
4
waveguides observation
4
observation parametric
4

Similar Publications

The role of surfactant proteins A and D (SP-A and SP-D) in lung clearance and translocation to secondary organs of inhaled nanoparticles was investigated by exposing SP-A and SP-D knockout (AKO and DKO) and wild type (WT) mice nose-only for 3 hours to an aerosol of 20 nm gold nanoparticles (AuNPs). Animals were euthanised at 0-, 1-, 7- and 28-days post-exposure. Analysis by inductively coupled plasma mass spectrometry (ICP-MS) of the liver and kidneys showed that extrapulmonary translocation was below the limits of detection.

View Article and Find Full Text PDF

A coherent concatenation of multiple solitary waves may lead to a stable infrared and visible broadband filament in a ceramic YAG polycrystal. This self-trapped soliton train is leveraged to implement self-referenced multiplex coherent anti-Stokes Raman scattering (SR-M-CARS) imaging. Simulations and experiments illustrating the filamentation process and the concatenation of focusing-defocusing cycles in ceramic and crystal YAG are presented.

View Article and Find Full Text PDF

Coherent Anti-Stokes Hyper-Raman Spectroscopy.

Nat Commun

January 2025

Department of Basic Science, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro, Tokyo, 153-8902, Japan.

Coherent Raman scattering spectroscopies have been established as a powerful tool for investigating molecular systems with high chemical specificity. The existing coherent Raman scattering techniques detect only Raman active modes, which are a part of the whole molecular vibrations. Here, we report the first observation of coherent anti-Stokes hyper-Raman scattering (CAHRS) spectroscopy, which allows measuring hyper-Raman active vibrations at high speed.

View Article and Find Full Text PDF

Spectroscopic study of energy transfer in collisions between vibrational excited H2 and CO2.

J Chem Phys

December 2024

Xinjiang Key Laboratory of Solid State Physics and Devices, Xinjiang University, Urumqi 830017, China.

The collisional energy transfer between vibrational excited H2(1, 7) and CO2 was investigated by exciting H2 to a vibrational excited state of v = 1, J = 7 by the stimulated Raman scattering technique. The coherent anti-Stokes Raman spectroscopy (CARS) technique determined that H2 was excited to the H2(1, 7) state. Varying the cuvette temperature, the number of H2(1, 7) particles was found to increase with the increase in H2 molar ratio α by scanning the intensity of the CARS spectrum, with peaks at different α at a temperature of 363 ± 15 K, but the peak temperature was not sensitive to α.

View Article and Find Full Text PDF

Harnessing Raman spectroscopy and multimodal imaging of cartilage for osteoarthritis diagnosis.

Sci Rep

December 2024

School of Chemistry, Faculty of Engineering and Physical Sciences, University of Southampton, Life Sciences Building 85, University Road, Highfield, Southampton, SO17 1BJ, UK.

Osteoarthritis (OA) is a complex disease of cartilage characterised by joint pain, functional limitation, and reduced quality of life with affected joint movement leading to pain and limited mobility. Current methods to diagnose OA are predominantly limited to X-ray, MRI and invasive joint fluid analysis, all of which lack chemical or molecular specificity and are limited to detection of the disease at later stages. A rapid minimally invasive and non-destructive approach to disease diagnosis is a critical unmet need.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!