A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Leaching of antimony from polyethylene terephthalate (PET) bottles into mineral water. | LitMetric

Leaching of antimony from polyethylene terephthalate (PET) bottles into mineral water.

Sci Total Environ

Department of Analytical Chemistry, Institute of Chemistry, L. Eötvös University, H-1117 Budapest, Pázmány Péter sétány 1/A, Hungary.

Published: August 2009

The Sb leaching from polyethylene terephthalate (PET) package material into 10 different brands of still (non-carbonated) and sparkling (carbonated) Hungarian mineral water purchased in supermarkets was investigated by inductively coupled plasma sector field mass spectrometry (ICP-SF-MS). The Sb concentration measured in PET package materials varied between 210 and 290 mg/kg. Generally, the Sb concentration of still mineral water was lower than that of sparkling in the case of identical storage time. For modelling improper storage conditions, storage time (10-950 days), temperature (22 degrees C-70 degrees C), illumination (dark vs. 23 W daylight lamp for 116 h) as well as bottle volume (0.5, 1.0 and 1.5 L) were taken into consideration. Under certain extreme light and temperature storage conditions, the Sb concentration of some samples exceeded the concentration value of 2 ng/mL. The extent of Sb leaching from the PET recipients of different brands of mineral water can differ by even one order of magnitude in experiments conducted under the same conditions. Thus, the adequate selection of the polymer used for the production of the PET bottle for the solar water disinfection (SODIS) procedure seems to ensure low Sb levels in the water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2009.04.025DOI Listing

Publication Analysis

Top Keywords

mineral water
16
polyethylene terephthalate
8
terephthalate pet
8
pet package
8
storage time
8
storage conditions
8
water
6
pet
5
leaching antimony
4
antimony polyethylene
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!