Synopsis Experience in a large manufacturing unit showed that splashes of undiluted shampoo only produced transient effects in the eyes of production and packaging staff; over the same period, very few complaints of eye irritation were received from shampoo users, none of which were of a serious nature. Predictive testing is needed to make sure that new formulations are not severe eye irritants though rabbit eye testing may tend to exaggerate the likely human response. Detergent concentration is the principal factor influencing findings in the rabbit eye and an active matter content of 2.5-3.0% (usually representing a 20% aqueous dilution of shampoo) gives the best discrimination between formulations whilst producing no signs of distress in the animals; for typical anionic shampoos, testing at this concentration is recommended, without subsequent rinsing. Rabbit eye tests should never be conducted at higher concentrations until their innocuousness at 20% dilution has been shown and, even then, stronger preparations should only be instilled if they contain new ingredients for which the potential risk in human use are unknown. Conduct of all rabbit eye testing as a comparison with a 'control' formulation of equivalent concentration, known to be well tolerated under market conditions, is recommended. For preliminary screening, an in vitro test using freshly-isolated buccal mucosa cells from human volunteers may be useful, irritancy being assessed by the proportion of cells showing loss of visible nuclei when examined by phase-contrast microscopy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1467-2494.1979.tb00206.x | DOI Listing |
Carbohydr Polym
March 2025
Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan; Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan; Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan; Research Center for Chinese Herbal Medicine, College of Human Ecology, Chang Gung University of Science and Technology, Taoyuan 33303, Taiwan; Center for Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan. Electronic address:
In this study, we aimed to develop ion-responsive and biocompatible alginate-capped nanoceria (Ce-ALG) for β-1,3-glucan (i.e., wound healing agent) delivery and corneal abrasion (CA) treatment.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
School of Pharmacy, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
Dexamethasone (Dex) is a primary medication for treating dry eye syndrome, and tobramycin-dexamethasone eye drops are commercially available. However, the eye's complex physiological environment reduces its bioavailability, and repeated use can lead to significant systemic toxicity and side effects. This study introduces a novel conjugate of chitosan (CS) and N-acetylcysteine (NAC), a bioadhesive material, which was grafted onto the surface of a Dex-supported nanostructured lipid carrier (NLC) to develop an innovative nanoparticle lipid ocular drug delivery system (CS-NAC@Dex-NLC).
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
College of Chemistry and Pharmacy, Northwest A&F University, Yangling, Shaanxi, 712100, P. R. China.
Bacterial keratitis (BK) is a type of corneal inflammation resulting from bacterial infection in the eye. Although nanozymes have been explored as promising materials in corneal wound healing, currently available nanozymes lack sufficient catalytic activity and the ability to penetrate bacterial biofilms, limiting their efficacy against the treatment of BK. To remedy this, ZnFe layered double hydroxide (ZnFe-LDH) nanosheets are loaded with Cu single-atom nanozymes (Cu-SAzymes) and aminated dextran (Dex-NH), resulting in the formation of the nanozyme DT-ZnFe-LDH@Cu, which possesses peroxidase (POD)-, oxidase (OXD)-, and catalase (CAT)-like catalytic activities.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, Beijing 100730, China.
Multiple ocular surface disorders are associated with the mechanical properties of the interface between the eyelid and cornea. Determining eyelid pressure is vital for diagnosing and preventing these disorders. However, current measurements rely on flat piezoresistive pressure sensor arrays that lack eye-motion sensing capabilities, resulting in discomfort and measurement inaccuracies.
View Article and Find Full Text PDFJ Pediatr Ophthalmol Strabismus
January 2025
Purpose: To investigate the effects of recession or re-section surgery on PAX 7 positive satellite cells of the extraocular muscle (EOM) in rabbits.
Methods: A total of 20 rabbits (40 eyes) were included in this study. The superior rectus muscle of the right eye was either recessed or resected.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!