Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The aim of this study was to compare, in a randomized multicenter trial, paclitaxel-eluting stents (CoStar, Conor Medsystems, Menlo Park, California) versus pimecrolimus-eluting stents (Corio, Conor Medsystems) versus stents with dual elution of both drugs (SymBio, Conor Medsystems) in native coronary arteries.
Background: The CoStar cobalt-chromium reservoir-based stent platform, eluting paclitaxel in a controlled way via a bioresorbable polymer, reduces restenosis versus its respective bare-metal stent. The reservoir system allows the use of other drugs targeted to different mechanisms involved in the process of vascular restenosis and simultaneous loading of multiple, synergistic drugs.
Methods: Patients with single de novo lesions were asymmetrically randomized to 1 of the 3 types of stent (1:2:2). Six-month coronary angiography was planned in all. The primary analysis was a noninferiority test for the primary end point of 6-month angiographic in-stent late lumen loss of Corio versus CoStar and SymBio versus CoStar. Secondary end points included binary angiographic restenosis and major adverse clinical events (cardiac death, myocardial infarction, target vessel revascularization).
Results: The trial was prematurely suspended after 246 patients were enrolled (planned enrollment: 375 patients): 49 patients received CoStar, 97 received SymBio, and 100 received Corio. In-stent late loss was significantly reduced with CoStar versus either SymBio or Corio (0.58 +/- 0.58 mm vs. 0.96 +/- 0.73 mm and 0.58 +/- 0.58 mm vs. 1.40 +/- 0.67 mm, p < 0.001 for both comparisons). Binary in-stent restenosis rates were, 7.1%, 20%, and 40.9%, respectively (p < 0.001 for both comparisons); 6-month major adverse cardiac event rates were, 2.0%, 14.4%, and 39.0%, respectively (p < 0.001 for both comparisons).
Conclusions: Stents eluting pimecrolimus or the dual combination of pimecrolimus and paclitaxel failed to show angiographic noninferiority when compared with paclitaxel-eluting stents. (A Randomized, Multi-Center Study of the Pimecrolimus-Eluting and Pimecrolimus/Paclitaxel-Eluting Coronary Stent Systems; NCT00322569).