A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The GENESIS (Randomized, Multicenter Study of the Pimecrolimus-Eluting and Pimecrolimus/Paclitaxel-Eluting Coronary Stent System in Patients with De Novo Lesions of the Native Coronary Arteries) trial. | LitMetric

Objectives: The aim of this study was to compare, in a randomized multicenter trial, paclitaxel-eluting stents (CoStar, Conor Medsystems, Menlo Park, California) versus pimecrolimus-eluting stents (Corio, Conor Medsystems) versus stents with dual elution of both drugs (SymBio, Conor Medsystems) in native coronary arteries.

Background: The CoStar cobalt-chromium reservoir-based stent platform, eluting paclitaxel in a controlled way via a bioresorbable polymer, reduces restenosis versus its respective bare-metal stent. The reservoir system allows the use of other drugs targeted to different mechanisms involved in the process of vascular restenosis and simultaneous loading of multiple, synergistic drugs.

Methods: Patients with single de novo lesions were asymmetrically randomized to 1 of the 3 types of stent (1:2:2). Six-month coronary angiography was planned in all. The primary analysis was a noninferiority test for the primary end point of 6-month angiographic in-stent late lumen loss of Corio versus CoStar and SymBio versus CoStar. Secondary end points included binary angiographic restenosis and major adverse clinical events (cardiac death, myocardial infarction, target vessel revascularization).

Results: The trial was prematurely suspended after 246 patients were enrolled (planned enrollment: 375 patients): 49 patients received CoStar, 97 received SymBio, and 100 received Corio. In-stent late loss was significantly reduced with CoStar versus either SymBio or Corio (0.58 +/- 0.58 mm vs. 0.96 +/- 0.73 mm and 0.58 +/- 0.58 mm vs. 1.40 +/- 0.67 mm, p < 0.001 for both comparisons). Binary in-stent restenosis rates were, 7.1%, 20%, and 40.9%, respectively (p < 0.001 for both comparisons); 6-month major adverse cardiac event rates were, 2.0%, 14.4%, and 39.0%, respectively (p < 0.001 for both comparisons).

Conclusions: Stents eluting pimecrolimus or the dual combination of pimecrolimus and paclitaxel failed to show angiographic noninferiority when compared with paclitaxel-eluting stents. (A Randomized, Multi-Center Study of the Pimecrolimus-Eluting and Pimecrolimus/Paclitaxel-Eluting Coronary Stent Systems; NCT00322569).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2008.12.011DOI Listing

Publication Analysis

Top Keywords

conor medsystems
12
randomized multicenter
8
study pimecrolimus-eluting
8
pimecrolimus-eluting pimecrolimus/paclitaxel-eluting
8
pimecrolimus/paclitaxel-eluting coronary
8
coronary stent
8
novo lesions
8
native coronary
8
paclitaxel-eluting stents
8
in-stent late
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!