Unlabelled: The impact of prior heat stress on subsequent aerobic exercise-heat performance has not been studied.

Purpose: To determine whether prior heat stress degrades subsequent aerobic exercise performance in the heat.

Methods: Eighteen nonheat acclimated males were trained (four practice trials) on an aerobic exercise performance test in 22 degrees C and then divided into two (n = 8) groups. One group (EUHPH; (.)VO2peak = 44 +/- 7 mL x kg x min(-1)) was tested after 90 min of recovery (in 22 degrees C) from 3 h of intermittent light-intensity (<30% (.)VO2peak) exercise-heat (50 degrees C) stress, where sweat losses were matched with fluid intake (3.5 +/- 0.5 L) to maintain euhydration. The other group (EUH; (.)VO2peak = 45 +/- 5 mL x kg x min(-1)) was tested while euhydrated without prior exercise-heat stress. Aerobic performance was determined from a 30-min cycling preload (50% (.)VO2peak) followed by a 15-min time trial in 40 degrees C. Total work during the 15-min performance time trial in EUH and EUHPH was compared, as were the percent changes from the best practice trials.

Results: Volunteers were euhydrated (plasma osmolality < 290 mOsm x kg(-1)) and normothermic before each exercise-heat trial. Heart rate and core temperature were not different (P > 0.05) between groups at any time point during exercise. Total work was not different (P > 0.05) at baseline or between EUH (150.5 +/- 28.3 kJ; 2.0 +/- 0.3 kJ x kg(-1)) and EUHPH (160.3 +/- 24.0 kJ; 1.8 +/- 0.2 kJ x kg(-1)). The percent change in total work relative to baseline was not different (P > 0.05) between EUH (-18.7% +/- 9.2%) and EUHPH (-15.0% +/- 7.8%).

Conclusions: If hydration and body temperatures recover, prior exercise-heat stress does not result in a greater degradation in aerobic time trial performance in the heat compared with heat exposure alone.

Download full-text PDF

Source
http://dx.doi.org/10.1249/MSS.0b013e3181988c14DOI Listing

Publication Analysis

Top Keywords

prior heat
12
heat stress
12
stress subsequent
8
time trial
8
trial performance
8
performance heat
8
subsequent aerobic
8
aerobic exercise
8
exercise performance
8
total work
8

Similar Publications

Introduction: is the gram-negative, facultative intracellular bacterium that causes the disease known as plague. Due to the risk for aerosol transmission, a low infectious dose, and the acute and lethal nature of pneumonic plague, research activities with require Biosafety Level 3 (BSL-3) facilities to provide the appropriate safeguards to minimize accidental exposures and environmental release. However, many experimental assays cannot be performed in BSL-3 due to equipment availability, and thus require removal of samples from the BSL-3 laboratory to be completed.

View Article and Find Full Text PDF

Chronic Kidney Disease of Unknown Etiology: A Global Health Threat in Rural Agricultural Communities-Prevalence, Suspected Causes, Mechanisms, and Prevention Strategies.

Pathophysiology

December 2024

Laboratory of Epidemiology and Research in Health Sciences, Faculty of Medicine and Pharmacy, Sidi Mohammed Ben Abdellah University, PO 1893, Km 2200, Route Sidi Harazem, Fez 30000, Morocco.

Chronic Kidney Disease of Unknown Etiology (CKDu) is a worldwide hidden health threat that is associated with progressive loss of kidney functions without showing any initial symptoms until reaching end-stage renal failure, eventually leading to death. It is a growing health problem in Asia, Central America, Africa, and the Middle East, with identified hotspots. CKDu disease mainly affects young men in rural farming communities, while its etiology is not related to hypertension, kidney stones, diabetes, or other known causes.

View Article and Find Full Text PDF

High-Performance Boiling Surfaces Enabled by an Electrode-Transpose All-Electrochemical Strategy.

Adv Sci (Weinh)

December 2024

Institute of Thermal Science and Power Systems, School of Energy Engineering, Zhejiang University, Hangzhou, 310027, China.

High-performance boiling surfaces are in great demand for efficient cooling of high-heat-flux devices. Although various micro-/nano-structured surfaces have been engineered toward higher surface wettability and wickability for enhanced boiling, the design and fabrication of surface structures for realizing both high critical heat flux (CHF) and high heat transfer coefficient (HTC) remain a key challenge. Here, a novel "electrode-transpose" all-electrochemical strategy is proposed to create superhydrophilic microporous surfaces with higher dendrites and larger pores by simply adding an electrochemical etching step prior to the multiple electrochemical deposition steps.

View Article and Find Full Text PDF

Grossly lipaemic samples are a significant cause of analytical errors, potentially impacting patient care. The causes of lipaemia are varied and often unavoidable, while methods to reduce lipaemia through gold-standard ultracentrifugation are limited by availability, transportation, and cost. Benchtop centrifugation has been proposed as an alternative method to reduce lipaemia.

View Article and Find Full Text PDF

Background: The objectives were to determine the prevalence of de novo and persistent pelvic pain after benign hysterectomy and to assess risk factors.

Methods: A Swedish prospective multicenter study of 440 women undergoing benign hysterectomy was conducted between October 2011 and March 2017. Measures of pain, the spatial extent of bodily pain, and pain sensitivity were assessed using a self-reporting questionnaire, Margolis's patient pain drawing, and quantitative sensory testing of pain thresholds for pressure, heat, and cold, respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!