Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate the image registration accuracy and efficiency of CT and MRI fusion using three algorithms in nasopharyngeal carcinoma (NPC).
Methods And Materials: Twelve sets of CT and MRI scans of 12 NPC patients were fused using three image registration algorithms, respectively: Mark-and-link, Interactive, and Normalized Mutual Information (NMI). Registration accuracy was evaluated by performing statistical analysis of the coordinate differences between CT and MR anatomical landmarks along the x-, y- and z-axes. The time required to complete the registration process using three algorithms was also recorded. One-way ANOVA was used to analyze the difference of the three registration methods.
Results: The mean time required for CT/MRI registration using the three different registration algorithms, mark-and-link, interactive, and NMI, was 6.25 min, 5.25 min, and 5.15 min, respectively. The mark-and-link method was more time consuming (F=8.74, p=0.001); however no statistical difference was found between the time required using interactive and NMI methods (p=0.77). Mean registration errors of the three methods along the x-axis were 0.66 mm, 0.70 mm, and 0.68 mm, respectively (F=0.09, p=0.91). Along the y-axis, the mean registration errors were 1.03 mm, 1.04 mm, and 1.03 mm, respectively (F=0.02, p=0.98). Along the z-axis, they were 0.58 mm, 0.64 mm, and 0.56 mm, respectively (F=0.21, p=0.81).
Conclusions: All three registration algorithms, mark-and-link, interactive, and NMI, can provide accurate CT/MRI registration. However the mark-and-link method was most time consuming.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720458 | PMC |
http://dx.doi.org/10.1120/jacmp.v10i2.2906 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!