Download full-text PDF |
Source |
---|
J Endovasc Ther
January 2025
Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, University of Bern, Bern, Switzerland.
Purpose: To perform a systematic review and meta-analysis of the outcomes of Anaconda fenestrated endograft for the treatment of complex abdominal aortic aneurysms (cAAA).
Material And Methods: A systematic search of all the literature reported until May 2024 was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The pooled 30-day mortality rate, technical success rate, reintervention rate as well as bridging stent occlusion rate, and corresponding 95% confidence intervals (CIs) were estimated using fixed or random effect methods.
J Clin Med
January 2025
Department of Accident and Emergency, Etlik City Hospital, Ankara 06170, Turkey.
Arterial diseases (ADs) are a significant health problem, with high mortality and morbidity rates. Endovascular interventions, such as balloon angioplasty (BA), bare-metal stents (BMSs), drug-eluting stents (DESs) and drug-coated balloons (DCBs), have made significant progress in their treatments. However, the issue has not been fully resolved, with restenosis remaining a major concern.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Department of Vascular Surgery, The Chaim Sheba Medical Center, Tel HaShomer, Ramat Gan, Israel.
Purpose: To report a case series on using a novel semi-branch feature in custom-made stent-grafts in the endovascular treatment of complex aortic aneurysms and summarize the contemporary usage of this technology.
Case Series: Four patients underwent endovascular aortic aneurysm repair (EVAR) with a custom-made semi-branch stent-graft (Semi-Branch Endovascular Aortic Aneurysm Repair [SBEVAR]). Two male patients, 75- and 76-year-old, were treated due to failed EVAR with late-type Ia endoleak, and the other two, 80- and 55-year-old male patients, due to a juxta-renal aortic abdominal aneurysm (JRAAA).
Pediatr Cardiol
January 2025
Department of Pediatrics, Section of Cardiology, Rady Children's Hospital, University of California-San Diego, San Diego, CA, USA.
Repair or palliation of pulmonary atresia with intact ventricular septum (PA/IVS) often falls into one of 4 categories: cardiac transplant, 2-ventricular circulation, 1.5 ventricle circulation, or single ventricle circulation. The optimal management strategy has been an area of much debate.
View Article and Find Full Text PDFCirc Cardiovasc Interv
January 2025
Department of Cardiology, Odense University Hospital, Denmark (K.N.H., J.T., M.N., M.H., J.E.-G., K.T.V., A.J., H.S.H., J.F.L., L.O.J.).
Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.
Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!