Objective: To compare 3 common sperm counting chambers by the computer-assisted sperm analysis (CASA) system and evaluate their precision in analyzing sperm density and motility.
Methods: We used latex bead solution at (20 +/- 5) x 10(6)/ml as analogue semen samples and analyzed the samples with Makler, Leja and Microcell counting chambers, 30 times with each chamber. And the average (x +/- s) and the coefficient of variation of sperm density were calculated by the CASA system. Meanwhile 54 semen samples collected from the outpatients analyzed with the 3 sperm counting chambers by the CASA system for the rates of forward movement and motility of the sperm.
Results: The averages of sperm density obtained with Makler, Leja and Microcell chambers were (25.90 +/- 3.97) x 10(6)/ml, (18.74 +/- 1.62) x 10(6)/ml and (20.35 +/- 2.55) x 10(6)/ml, the coefficients of variation were 15.31%, 8.64% and 12.54%, the rates of sperm forward movement were (46.54 +/- 17.09)%, (30.65 +/- 14.88)% and (30.49 +/- 13.21)%, and the rates of sperm motility were (59.75 +/- 16.12)%, (46.76 +/- 14.11)%, (43.11 +/- 14.02)% respectively. There were significant differences in average sperm density among the 3 groups (P < 0.05). The rates of sperm forward movement and motility obtained with the Makler chamber were significantly higher than those achieved with the Leja chamber and Microcell chamber (P < 0.05), but there were no significant differences between the latter two (P > 0.05).
Conclusion: The rates of sperm density obtained with the 3 sperm counting chambers differed significantly. In the analysis of sperm motility, a higher rate can be achieved with the coverslip-pressed chamber than the capillary-drawn chamber.
Download full-text PDF |
Source |
---|
Int Ophthalmol
January 2025
Ophthalmology Department, Faculty of Medicine - Suez Canal University Hospitals, 4.5 Kilo - Ring Road, Ismailia, 41522, Egypt.
Purpose: To assess the effect of anterior chamber depth on corneal endothelium using specular microscopy following uneventful phacoemulsification among cataract patients with different axial lengths.
Methods: The study was conducted in a quasi-experimental design including 300 eyes of 300 patients with grade three age-related nuclear cataract distributed equally based on their axial length into three equal groups. All eyes had grade three nuclear cataract.
Arq Bras Oftalmol
January 2025
Department of Ophthalmology and Visual Sciences, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Purpose: This study aimed to report the use, efficacy, and safety of intracameral voriconazole as an adjuvant treatment for deep fungal keratitis.
Methods: This was a prospective case series of seven eyes with fungal keratitis with anterior chamber involvement or a corneal ulcer refractory to conventional topical treatment. In addition to topical treatment with 0.
Future Cardiol
January 2025
Echocardiography research Center, Rajaie cardiovascular medical and research Center, Iran University of Medical Science, Tehran, Iran.
Introduction: Decreased left atrial appendage emptying velocity (LAAV) is a marker for thrombus formation. This study evaluates the association between LAAV and inflammatory indices in non-valvular atrial fibrillation (AF) patients.
Methods: The study population was 1428 patients with AF, 875 of whom enrolled.
Zhonghua Yi Xue Za Zhi
January 2025
Ophthalmology Center, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou310009, China.
To develop and validate a predictive model for assessing the risk of early postoperative high intraocular pressure (HIOP) following posterior chamber intraocular lens implantation. The clinical data of patients who underwent posterior chamber intraocular lens implantation at the Second Affiliated Hospital of Zhejiang University School of Medicine between May 2023 and April 2024 were retrospectively reviewed. Patients were divided into a modeling group and a validation group with a 7∶3 ratio using computerized random allocation.
View Article and Find Full Text PDFInhal Toxicol
January 2025
Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA.
: Pulmonary exposure to emissions from manipulating solid surface composite (SSC) materials has been associated with adverse health effects in humans and laboratory animals. Previous and investigations of SSC toxicity have been limited by particle delivery methods that do not fully recapitulate the workplace environment. This study sought to determine the acute SSC-induced pulmonary responses whole-body inhalation exposure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!