Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: To compare recurrence rate and other procedural characteristics in patients undergoing atrioventricular nodal re-entrant tachycardia (AVNRT) treatment with catheter cryoablation (CRYO) delivered by 6 mm-tip catheter or radiofrequency (RF) ablation.
Methods And Results: This is a retrospective case-control study including 80 patients with AVNRT treated with CRYO from March 2002 to June 2008. They were compared with another 80 consecutive patients who underwent RF ablation for AVNRT within the same period. Procedural success of 97.5 and 95% were achieved in CRYO and RF group, respectively. There was no permanent atrioventricular block (AVB) in the CRYO group, whereas two (2.5%) patients developed permanent first-degree or second-degree AVB in RF group (P = 0.155). Higher recurrence was found in the CRYO group (9 vs. 1.3%; P = 0.032) with no difference in the composite endpoint of procedural failure and recurrence between the groups (P = 0.263). There was significantly shorter fluoroscopy time (18.6 +/- 10.8 vs. 25.9 +/- 17.0 min; P = 0.002) and more energy applications required (3.1 +/- 1.7 vs. 1.9 +/- 1.1; P < 0.001) in the CRYO than the RF group.
Conclusion: Compared with RF ablation, CRYO with 6 mm-tip catheter for treating AVNRT results in higher recurrence and potentially lower incidence of permanent AVB. Fluoroscopy time has been shown to be reduced by CRYO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/eup121 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!