Background: Concomitant ipsilateral femoral shaft and neck fractures present a challenge to the orthopaedic surgeon, and no consensus has yet emerged on the optimal treatment method. We report the results of a retrospective study of 43 patients with these complex fractures who were treated at a single Level 1 trauma centre.

Patients And Methods: The study participants consisted of 28 males and 15 females with a mean age of 43 years. The mean follow-up period was 48 months. Four different treatment methods were used: (1) antegrade reamed intramedullary nailing of the shaft with cancellous screw fixation of the neck, (2) dynamic hip screw (DHS) fixation of the neck and low-contact dynamic compression plate (LCDCP) fixation of the shaft, (3) cancellous screw fixation of the neck and LCDCP fixation of the shaft, and (4) reconstruction nailing of both shaft and neck.

Results: No statistically significant differences in amount of blood loss, duration of surgery, total complication rate, nor clinical results were found among the four treatment methods. For femoral neck fracture, however, the complication rate of cannulated screw with antegrade intramedullary nailing fixation was 11 times that of DHS with LCDCP fixation.

Conclusions: Antegrade nail with screw fixation is not a recommended treatment method in patients with ipsilateral femoral shaft and neck fractures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2009.03.009DOI Listing

Publication Analysis

Top Keywords

screw fixation
12
fixation neck
12
femoral neck
8
ipsilateral femoral
8
femoral shaft
8
shaft neck
8
neck fractures
8
treatment method
8
treatment methods
8
intramedullary nailing
8

Similar Publications

Preserving Cervical Mobility: A Novel Robot-Assisted Approach for Atlas Fracture Fixation.

Am J Case Rep

January 2025

Department of Orthopedic Surgery, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.

BACKGROUND The management of unstable atlas fractures remains a subject of ongoing debate and controversy. The conservative surgical treatment commonly involves fusion, resulting in severe loss of cervical spine mobility, and a large incisions and extensive tissue dissection are required. We aim to introduce a novel concept and surgical approach for treating atlas fracture, one that involves minimizing trauma while maintaining mobility of the upper cervical spine without resorting to fusion.

View Article and Find Full Text PDF

Unlabelled: Mandibular reconstruction is essential for restoring both function and aesthetics after segmental resection due to tumoral pathology. This study aimed to conduct a comparative analysis of three reconstruction strategies for defects resulting from segmental mandibular resection, utilizing finite element analysis (FEA).

Methods: A digital model of the mandible was created from CBCT data and optimized for FEA.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Valgus-impacted femoral neck fractures (OTA 31B1.1 and 31B1.2) are considered stable fractures with favorable outcomes compared to displaced fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!