Treatment of venous aortorenal bypass graft aneurysm using a stent-graft.

Cardiovasc Intervent Radiol

Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.

Published: February 2010

We present the case of a 77-year-old male patient who had undergone a bilateral venous aortorenal bypass graft 30 years previously. Thirteen years previously, the patient was shown to have a decrease in renal function, with mild shrinking of both kidneys; additionally, a stenosis was found in the left proximal anastomosis. At the most recent follow-up visit (1 year previously), ultrasound revealed an aneurysm (42 mm in diameter) of the left renal bypass graft; the finding was confirmed by CT angiography. A significant ostial stenosis of the left renal bypass graft was also confirmed. It was decided to place a self-expandable stent-graft into the aneurysm while also attempting to dilate the stenosis. Proximal endoleak after stent-graft placement necessitated the implantation of another, balloon-expandable stent-graft into the bypass graft ostium. Postprocedural angiography and follow-up by CT angiography at 3 months confirmed good patency of the stent-grafts and complete thrombosis of the aneurysmal sac, with preserved kidney perfusion. Renal function remained unaltered, while the hypertension is better controlled.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-009-9579-6DOI Listing

Publication Analysis

Top Keywords

bypass graft
20
venous aortorenal
8
aortorenal bypass
8
renal function
8
stenosis left
8
left renal
8
renal bypass
8
bypass
5
graft
5
treatment venous
4

Similar Publications

Background & Aim: The definition and clinical relevance of percutaneous coronary intervention (PCI)-related myocardial infarction (MI) has been a topic of significant debate and controversy. It has particularly garnered widespread attention recently due to a contemporary trend of including it as a component of primary end points in major trials. The study aimed to assess the clinical relevance of PCI-related MI (PMI) according to the Fourth Universal Definition of MI using a high-sensitivity troponin (hs-Tn) assay in a real-world setting.

View Article and Find Full Text PDF

Disparities in 180-day Infection Rates Following Coronary Artery Bypass Grafting and Aortic Valve Replacement.

J Thorac Cardiovasc Surg

January 2025

Department of Cardiac Surgery, Michigan Medicine, University of Michigan, Ann Arbor, MI; The Michigan Society of Thoracic and Cardiovascular Surgeons Quality Collaborative, Ann Arbor, MI. Electronic address:

Objective: To compare sex and racial differences in 180-day infection rates after coronary artery bypass grafting (CABG) and aortic valve replacement (AVR).

Methods: A Statewide Society of Thoracic Surgeons Adult Cardiac Surgery Database was linked to Medicare claims data to identify 8,887 beneficiaries undergoing CABG and AVR (surgical or transcatheter) between 2017 and 2021. The primary outcome was the incidence of 180-day infection.

View Article and Find Full Text PDF

In coronary artery bypass grafting (CABG), the use of the left internal mammary artery (LIMA) is considered the gold standard. The conventional technique of using electrocautery for LIMA harvesting is associated with adverse events. In this study, we used a different technique that combined carbon dioxide with electrocautery to harvest LIMA and compared it with the conventional electrocautery method.

View Article and Find Full Text PDF

Background: Literature is not clear whether women experience increased mortality and adverse events after coronary artery bypass grafting (CABG). Studies have shown that women had comparative outcomes to men in off-pump CABG (OPCAB). Hence, we undertook this study to understand the short- and long-term outcomes of women compared to men after OPCAB.

View Article and Find Full Text PDF

The transcatheter management of complex cardiovascular diseases has significantly evolved, offering less invasive alternatives to traditional surgical interventions. In this report we describe 2 cases of patients who developed ascending aortic pseudoaneurysms soon after coronary artery bypass grafting. With meticulous computed tomography angiography planning and with live intracardiac echography, these patients underwent successful transcatheter repair using a 6/4-mm Amplatzer Duct Occluder II (Abbott) vascular plug.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!