The human sacrum is the target of lumbosacral instrumentation and decompression procedures. Such surgical interventions require detailed knowledge of the anatomy of the human sacrum. The aim of this study was to measure surgically relevant parameters. Several factors, including the one-piece composition of the sacrum, the angles of the sacral pedicles and the anteroposterior diameter of the sacral vertebral bodies distinguish the sacrum from other parts of spine. Thirty-two measurements of shape, angles and distances between parts were taken of the sacra of 100 adult West Anatolian people using a Vernier caliper accurate to 0.1 mm and goniometer. According to this morphometric study, when measured from the sagittal, the S1 facet angle was measured as 35.71 degrees +/-9.59 and 34.70 degrees +/-9.66, the sacral pedicle anteromedial screw trajectory angle was 35.65 degrees +/-4.73 and 31.95 degrees +/-3.95 and the anterolaterally oriented sacral wing screw trajectory angle was 32.65 degrees +/-3.51 and 29.10 degrees +/-3.14, on the right and left sides, respectively. The distance of the midline oriented S1 pedicle screw was 51.12 mm and 51.26 mm on the right and left side, respectively. The distance for sacral wing oriented screw placement was 50.13 mm and 50.46 mm on the right and left side, respectively. The anteroposterior and transverse diameter of the sacral spinal canal were 21.81 mm and 31.31 mm, respectively. Thus, this study describes anatomical specifications of the sacrum. These defined morphometric details should be taken into consideration during surgical procedures. This study also describes anatomical landmarks which will allow injury of the sacrum during surgery to be avoided.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2008.07.081DOI Listing

Publication Analysis

Top Keywords

human sacrum
12
screw placement
8
diameter sacral
8
screw trajectory
8
trajectory angle
8
sacral wing
8
left side
8
study describes
8
describes anatomical
8
sacrum
6

Similar Publications

Evidence for Endogenous Collagen in Fossil Bone.

Anal Chem

January 2025

Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3BX, U.K.

Reports of proteins in fossilized bones have been a subject of controversy in the scientific literature because it is assumed that fossilization results in the destruction of all organic components. In this paper, a novel combination of analytical techniques is used to address this question for an exceptionally well-preserved sacrum excavated from the Upper Cretaceous strata of the South Dakota Hell Creek Formation. Cross-polarized light microscopy (XPol) shows birefringence consistent with collagen presence.

View Article and Find Full Text PDF

Childbirth is a dynamic process involving mutual adaptation between the maternal pelvis and the presenting fetal part. The ability of the pelvis to maintain optimal mobility during labor plays a crucial role in achieving favorable obstetric outcomes. The pubic arch angle (PAA) increases amplitude during pregnancy, showing pelvic tissue adjustment.

View Article and Find Full Text PDF

Unlabelled: To investigate the effects of differing treadmills on impact acceleration and muscle activation.

Methods: 15 males and 7 females (27.8 ± 7.

View Article and Find Full Text PDF

Background: Sacrocolpopexy has become a favored treatment of pelvic organ prolapse due to its durability and efficacy. Sacrocolpopexy has not been standardized and there is no categorization scheme to facilitate communication or research efforts for the procedure. A systematic review was conducted to facilitate construction of a classification system for sacrocolpopexy based on extent of vaginal dissection described in the medical literature.

View Article and Find Full Text PDF

Iliosacral screw osteosynthesis - state of the art.

Arch Orthop Trauma Surg

January 2025

Department of Orthopedics and Traumatology, University Medical Center Mainz, Mainz, Germany.

Iliosacral screw osteosynthesis is a widely recognized technique for stabilizing unstable posterior pelvic ring injuries, offering notable advantages, including enhanced mechanical stability, minimal invasiveness, reduced blood loss, and lower infection rates. However, the procedure presents technical challenges due to the complex anatomy of the sacrum and the proximity of critical neurovascular structures. While conventional fluoroscopy remains the primary method for intraoperative guidance, precise preoperative planning using multiplanar reconstructions and three-dimensional volume rendering is crucial for ensuring accurate placement of iliosacral or transsacral screws.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!