Quantitation of metabolites by 1H NMR.

Magn Reson Med

Department of Molecular Biophysics and Biochemistry, Yale University, New Haven, Connecticut.

Published: July 1991

In this report we describe the three factors that need to be measured when quantitating an edited resonance relative to an internal standard using a surface coil. These factors are necessary by virtue of the water, fat suppressing, and localization schemes used in studing a 1H metabolite. First, use of semi-selective pulses requires amplitude correction of the edited and reference resonances. Second, use of a single surface coil results in different sensitive volumes for different resonances due to the inhomogeneous B1 and therefore require separate acquisition of the resonances. Third, editing pulses alter the sensitive volumes and this correction must be made internally by applying the same editing pulse to the reference resonance. A rationalization of this correction is given in terms of rotation operators. We apply these corrections to quantitate edited lactate relative to total creatine in a MnCl2-doped phantom and find 91% rather than 145% of known concentration. In human skeletal muscle in vivo after exhaustive exercise, we measured the lactate after exercise and found it to be 27.2 mM in two experiments, in reasonable agreement with literature values for the given exercise protocol.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.1910200106DOI Listing

Publication Analysis

Top Keywords

surface coil
8
sensitive volumes
8
quantitation metabolites
4
metabolites nmr
4
nmr report
4
report describe
4
describe three
4
three factors
4
factors measured
4
measured quantitating
4

Similar Publications

Recent progress in digital microfluidics has revealed the distinct advantages of liquid marbles, such as minimal surface friction, reduced evaporation rates, and non-wettability compared to uncoated droplets. This study provides a comprehensive examination of an innovative technique for the precise, contamination-free manipulation of non-magnetic water liquid marbles (WLMs) carried by a ferrofluid liquid marble (FLM) under the control of direct current (DC) and pulse-width modulation (PWM) magnetic fields. The concept relies on the phenomenon in which an FLM and WLMs form a shared meniscus when placed together on a water surface, causing the WLMs to closely track the magnetically actuated FLM.

View Article and Find Full Text PDF

Bacteriocins, naturally derived antimicrobial peptides, are considered promising alternatives to traditional preservatives and antibiotics, particularly in food and medical applications. Despite extensive research on various bacteriocins, cyclic varieties remain understudied. This study introduces Gassericin GA-3.

View Article and Find Full Text PDF

Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.

View Article and Find Full Text PDF

The coiled-coil protein carrier structure affects the activation of certain endocytosis pathways.

RSC Adv

January 2025

Graduate School of Environmental Symbiotic System Major, Nippon Institute of Technology 4-1 Gakuendai, Miyashiro Saitama 345-8501 Japan.

Coiled-coil protein carrier (CCPC) 140 is a rigid and anisotropically structured cationic coiled-coil artificial protein that has displayed up to a 1000 times higher level of cellular internalization activity than that of unstructured cell-penetrating peptides. Previous studies have demonstrated that CCPC 140's rigid and anisotropic structural properties and cationic surface properties are important for its superior cellular internalization activity. In this study, we investigated whether each physicochemical characteristic of CCPC 140 effectively contributed to activating the cellular internalization pathway.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!