We describe a new wave-front sensor based on the previously proposed pyramid sensor. This new sensor uses an extended source instead of a point-like source avoiding in this manner the oscillation of the pyramid. After an introductory background the sensor functioning is described. Among other possible optical testing uses, we apply the sensor to measure the wave-front aberration of the human eye. An experimental system built to test this specific application is described. Results obtained both in an articficial eye and in a real eye are presented. A discussion about the sensor characteristics, the experimental results and future work prospects is also included.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.10.000419DOI Listing

Publication Analysis

Top Keywords

extended source
8
wave-front sensor
8
human eye
8
sensor
7
source pyramid
4
pyramid wave-front
4
sensor human
4
eye
4
eye describe
4
describe wave-front
4

Similar Publications

Resolving the Ambiguity of Thermal Reversion in a Nonconjugated Monocyclic Diene-Based Photoswitch for Rechargeable Solar Thermal Batteries.

J Phys Chem A

January 2025

Laboratory of Advanced Computation and Theory for Materials and Chemistry, Department of Chemistry, National Institute of Technology Warangal (NITW), Warangal, Telangana 506004, India.

We report nonconjugated monocyclic dienes (nCMDs) as unique photoswitchable molecules that hold promise for harvesting substantial solar energy and storing it for extended durations. Herein, cyclohepta-1,4-diene and its N-heterocyclic analogue have been considered as prototypical models for investigating photoswitching behavior in nCMDs. Initially, the nonradiative deactivation pathway of nCMD from the low-lying excited state to the [2 + 2]-cycloadduct has been evaluated.

View Article and Find Full Text PDF

OpenMS WebApps: Building User-Friendly Solutions for MS Analysis.

J Proteome Res

January 2025

Applied Bioinformatics, Department of Computer Science, University of Tübingen, Tübingen 72074, Germany.

Liquid chromatography-mass spectrometry (LC-MS) is an indispensable analytical technique in proteomics, metabolomics, and other life sciences. While OpenMS provides advanced open-source software for MS data analysis, its complexity can be challenging for nonexperts. To address this, we have developed OpenMS WebApps, a framework for creating user-friendly MS web applications based on the Streamlit Python package.

View Article and Find Full Text PDF

Background: While an extensive body of research in palliative care exists on the experiences of grief and bereavement among family caregivers, much of this research is based on normative assumptions of who family caregivers are - housed, financially stable, and with extended family and/or friends to draw on for support. Research shows that in contexts of social disadvantage(e.g.

View Article and Find Full Text PDF

The radiation exposure to bystanders from nuclear medicine patients is a common concern raised in nuclear medicine departments. The GATE (Geant4 Application for Tomographic Emission) Monte Carlo radiation transport application was used to estimate the dose to a bystander. Two voxelised phantoms were utilised in a GATE Monte Carlo simulation as the radiation source and target.

View Article and Find Full Text PDF

This study investigates the use of nano-sized oxygen bubbles (NOBs) to enhance BTEX (benzene, toluene, ethylbenzene, xylene) biodegradation in groundwater. Optimized NOBs, averaging 155 nm and at a concentration of 6.59 × 10⁸ bubbles/mL, were found to provide sustained oxygen release with a half-life of approximately 50 days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!