A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using scattering and absorption spectra as MCR-hard model constraints for diffuse reflectance measurements of tablets. | LitMetric

One of the most often used tools in process analytical technology (PAT) is NIR spectroscopy as a non-destructive fast and reliable method to identify and quantify active pharmaceutical ingredients (API) in tablets. Very little work has been devoted to analyse the effects of scatter on quantitative analysis of the chemical composition. A novel approach to compensate scatter in reflectance spectroscopy which is more science based will be presented here. The basic assumption is to determine in step 1 a separate scattering spectral fingerprint, denoted as S spectra, and an absorption spectral fingerprint, denoted as K spectra. In the second step, the two spectra may then be used as input to the alternating least square (ALS) algorithm in multivariate curve resolution (MCR) in order to account for the spectral distortions due to the interaction of scatter and absorption. Standard tablets with a mass of 1.5 g and a diameter of 20 mm (thickness approx. 3.4 mm, optically infinite) were prepared according to a central composite design by mixing theophylline, magnesium stearate and cellactose at three different compactions of 31, 156 and 281 MPa. The samples are measured by an UV/Vis/NIR spectrometer attached with an integrating sphere in the wavelength range from 500 up to 2100 nm. The diffuse reflectance spectra of the center point sample with an optically infinite thickness R(infinity) as well as a sample of finite thickness R(0) ("optically thin") is measured as reference for the S and K spectra which are then calculated with the exponential solution of the Kubelka-Munk equation. After normalization, the S spectrum and the K spectrum of a single tablet are integrated as hard model constraints into the MCR-ALS procedure. In comparison to PLS modeling with EMSC pretreatment of the spectra, the hard model constrained MCR-ALS algorithm results in an improved prediction of the concentration of the API together with a higher robustness of the calibration models.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2009.01.057DOI Listing

Publication Analysis

Top Keywords

model constraints
8
diffuse reflectance
8
spectral fingerprint
8
fingerprint denoted
8
denoted spectra
8
optically infinite
8
hard model
8
spectra
7
scattering absorption
4
absorption spectra
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!