Background: Aseptic loosening of the stem, ranging from mild periprosthetic lucency to symptomatic loosening leading to implant removal, has been reported in press fit radial head prostheses.
Hypothesis: The purpose of this study was to determine the effect of the stem diameter and insertion force on initial stability with a press fit radial head prosthesis designed for bone ingrowth.
Materials And Methods: Cadaveric radii were implanted with radial head prostheses of increasing stem diameter. The insertion forces for each rasp and stem were measured. Micromotion of the stem at the isthmus of the canal and stem tip were measured under circumstances simulating eccentric loads.
Results: Insertion forces for all submaximum-sized rasps were similar. However, the insertion force for the maximum-sized rasp was approximately twice as large, and the insertion force for the oversized rasp was twice as large again, potentially indicating that the insertion force may be useful as a guide for determining appropriate stem size. Micromotions of the maximum diameter stem (isthmus, 41 microm; tip, 64 microm) were near the threshold for bone ingrowth, whereas the micromotions of the submaximum stem (isthmus, 253 microm; tip, 394 microm) were above this threshold.
Discussion: The maximum diameter stem achieved greater stability (minimum micromotion) compared with the submaximum diameter stem.
Conclusion: The best fixation strength in the press fit radial head prosthesis was achieved by maximum sizing in the neck canal.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2009.02.014 | DOI Listing |
Eur Radiol Exp
January 2025
Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.
Background: We evaluated the accuracy of magnetic resonance imaging (MRI) computed tomography (CT)-like sequences compared to normal-resolution CT (NR-CT) and super-high-resolution CT (SHR-CT) for planning of cochlear implantation.
Methods: Six cadaveric temporal bone specimens were used. 3-T MRI scans were performed using radial volumetric interpolated breath-hold (STARVIBE), pointwise-encoding time reduction with radial acquisition (PETRA), and ultrashort time of echo (UTE) sequences.
J Neurooncol
January 2025
Department of Neurosurgery, Hadassah-Hebrew University Medical Center, Jerusalem, Israel.
Purpose: Diffusing alpha-emitters Radiation Therapy ("Alpha DaRT") is a new cancer treatment modality that employs radium-224-loaded metal sources implanted in solid tumors to disperse alpha-emitting atoms within a therapeutic "kill-zone" of a few millimeters around each source. Preclinical studies have demonstrated tumor growth delay in various cancer types, including glioblastoma multiforme, and the method is used in clinical trials for patients with skin and head and neck cancer. This study aims to assess the safety and feasibility of implementing Alpha DaRT for brain tumor treatment in a large animal model.
View Article and Find Full Text PDFCureus
December 2024
Orthopedics and Traumatology, Istanbul University-Cerrahpasa, Istanbul, TUR.
Indian J Plast Surg
December 2024
Department of Plastic and Reconstructive Surgery, Nizam's Institute of Medical Sciences, Hyderabad, Telangana, India.
Traditionally, burn reconstructions have been performed by the use of skin grafting or local flaps. Recently free flaps are being used with increasing frequency. Although not very common in the head neck region, free flaps are mostly used for secondary reconstructions of cervicofacial contractures.
View Article and Find Full Text PDFSurg Radiol Anat
December 2024
Department of Hand-Foot Microsurgery, Shenzhen Nanshan People's Hospital, No. 89 Taoyuan Road, Nanshan District, Shenzhen, 518052, China.
Objective: This study explored the surgical technique and clinical application of the dorsal metacarpal cutaneous branch flap of the radial digital artery of the index finger.
Methods: Through the anatomical dissection of 10 hand specimens, we examined the origin and characteristics of the artery and its branches towards the hand dorsum. Furthermore, the soft tissue defects of the index finger in 12 patients admitted to our hospital between 2017 and 2021 were surgically repaired using the dorsal metacarpal cutaneous branch flap of the radial digital artery of the index finger.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!