Different second-order multivariate calibration algorithms, namely parallel factor analysis (PARAFAC), N-dimensional partial least-squares (N-PLS) and multivariate curve resolution-alternating least-squares (MCR-ALS) have been compared for the analysis of four fluoroquinolones in aqueous solutions, including some human urine samples (additional four fluoroquinolones were simultaneously determined by univariate calibration). Data were measured in a short time with a chromatographic system operating in the isocratic mode. The detection system consisted of a fast-scanning spectrofluorimeter, which allows one to obtain second-order data matrices containing the fluorescence intensity as a function of retention time and emission wavelength. The developed approach enabled us to determine eight analytes, some of them with overlapped profiles, without the necessity of applying an elution gradient, and thus significantly reducing both the experimental time and complexity. The study was employed for the discussion of the scopes of the applied second-order chemometric tools. The quality of the proposed technique coupled to each of the evaluated algorithms was assessed on the basis of the figures of merit for the determination of fluoroquinolones in the analyzed water and urine samples. Univariate calibration of four analytes led to limits of detection in the range 20-40 ng mL(-1) and root mean square errors for the validation samples in the range 30-60 ng mL(-1) (corresponding to relative prediction errors of 3-8%). The ranges for second-order multivariate calibration (using PARAFAC and N-PLS) of the remaining four analytes were: limit of detection, 2-8 ng mL(-1), root mean square errors, 3-50 ng mL(-1) and relative prediction errors, 1-5%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2009.04.033 | DOI Listing |
Anal Chem
January 2025
Laboratorio de Investigación y Desarrollo en Métodos Analíticos (LIDMA), Facultad de Ciencias Exactas, Universidad Nacional de La Plata (UNLP), Calle 49 y 115 (B1900AJL), La Plata 1900, Argentina.
A new strategy is proposed for second-order data fusion based on the simultaneous modeling of two data sets using the multivariate curve resolution-alternating least-squares (MCR-ALS) model, applying a new constraint during the ALS stage, called "Proportionality of Scores". This approach allows for the fusion of data from different sources, without requiring common dimensionality, and enables the application of specific constraints to each data set. This strategy was applied to the determination of five pharmaceutical contaminants (naproxen, danofloxacin, ofloxacin, sarafloxacin, and enoxacin) in environmental water samples, by fusing two sets of excitation-emission fluorescence matrices, measured before and after photochemical derivatization.
View Article and Find Full Text PDFJ Aquat Anim Health
December 2024
Department of Health Management and Centre for Veterinary Epidemiological Research, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada.
Objective: The primary objective was to construct a time series model for the abundance of the adult female (AF) sea lice Lepeophtheirus salmonis in Atlantic Salmon Salmo salar farms in the Bay of Fundy, New Brunswick, Canada, for the period 2016-2021 and to illustrate its short-term predictive capabilities.
Methods: Sea lice are routinely counted for monitoring purposes, and these data are recorded in the Fish-iTrends database. A multivariable autoregressive linear mixed-effects model (second-order autoregressive structure) was generated with the outcome of the abundance of AF sea lice and included treatments, infestation pressures (a measure that represents the dose of exposure of sea louse parasitic stages to potential fish hosts) within sites (internal) and among sites (external), and other predictors.
Crown ether is widely used in water purification because of its ring structure and good selective adsorption of specific heavy metals. However, its high cost and difficulty in recycling limit the purification of heavy metals in water. The anisotropic [2,4]-dibenzo-18-crown-6-modified bamboo pulp aerogel (DB18C6/PA) is successfully synthesized by microwave irradiation and directional freezing technology.
View Article and Find Full Text PDFAnal Bioanal Chem
December 2024
Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, 3000, Santa Fe, Argentina.
Flavonoids are particularly interesting because they have a broad spectrum of biological effects, including antioxidant and free radical scavenging activities. In this work, solid-liquid microextraction and dispersive liquid-liquid microextraction enhanced by ultrasound were developed and compared with the conventional method (Soxhlet extraction) to optimize the extraction of four flavonoids: rutin, quercitrin, quercetin, and myricetin in samples of Schinus molle (Aguaribay). During the development of the analytical method, different chemometric tools were used to optimize the microextraction procedure.
View Article and Find Full Text PDFInorg Chem
December 2024
School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, China.
Water pollution resulting from Hg(II) ions has garnered significant global concern for public health. The flexibility and simplicity of design, cost savings, and ease of operation with adaptive designs provide adsorption with a considerable advantage over other processes. However, MoS is hydrophobic in nature, which limits its efficiency in the removal of Hg(II) ions from water.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!