We present a rapidly fabricated micro-capillary electrophoresis chip that utilizes surface-tension-driven flow for sample injection and extraction of DNA. Surface-tension-driven flow (i.e. passive pumping) [G. M. Walker et al., Lab. Chip. 2002, 2, 131-134] injects a fixed volume of sample that can be predicted mathematically. Passive pumping eliminates the need for tubing, valves, syringe pumps, and other equipment typically needed for interfacing with microelectrophoresis chips. This method requires a standard micropipette to load samples before separation, and remove the resulting bands after analysis. The device was made using liquid phase photopolymerization to rapidly fabricate the chip without the need of special equipment typically associated with the construction of microelectrophoresis chips (e.g. cleanroom) [A. K. Agarwal et al., J. Micromech. Microeng. 2006, 16, 332-340; S. K. Mohanty et al., Electrophoresis 2006, 27, 3772-3778]. Batch fabrication time for the device presented here was 1.5 h including channel coating time to suppress electroosmotic flow. Devices were constructed out of poly-isobornyl acrylate and glass. A standard microscope with a UV source was used for sample detection. Separations were demonstrated using Promega BenchTop 100 bp ladder in hydroxyl ethyl cellulose (HEC) and oligonucleotides of 91 and 118 bp were used to characterize sample injection and extraction of DNA bands. The end result was an inexpensive micro-capillary electrophoresis device that uses tools (e.g. micropipette, electrophoretic power supplies, and microscopes) already present in most labs for sample manipulation and detection, making it more accessible for potential end users.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2842211PMC
http://dx.doi.org/10.1002/elps.200800595DOI Listing

Publication Analysis

Top Keywords

micro-capillary electrophoresis
12
surface-tension-driven flow
12
electrophoresis device
8
sample injection
8
injection extraction
8
extraction dna
8
passive pumping
8
equipment typically
8
microelectrophoresis chips
8
sample
5

Similar Publications

A handheld-type total integrated capillary electrophoresis system for SARS-CoV-2 diagnostics: Power, fluorescence detection, and data analysis by smartphone.

Biosens Bioelectron

January 2022

Department of Chemical Engineering (BK21 FOUR Integrated Engineering Program), Kyung Hee University, 1 Seochon-dong, Giheung-gu, Yongin-si, Gyeonggi-do, 17140, Republic of Korea. Electronic address:

A micro-capillary electrophoresis (μCE) system is one of the widely adopted techniques in the molecular diagnostics and DNA sequencing due to the benefits of high resolution, rapid analysis, and low reagent consumption, but due to the requirements of bulky high-power suppliers and an expensive laser-induced fluorescence detector module, the conventional set-up of μCE system is not adequate for point-of-care (POC) molecular diagnostics. In this study, we constructed a miniaturized and integrated μCE system which can be manipulated by a smartphone. The smartphone not only powers two boost converters and an excited laser, but also controls the relay for the power switch.

View Article and Find Full Text PDF

Human c-KIT oncogene is known to regulate cell growth and proliferation, and thus, acts as a probable target in the treatment of gastrointestinal tumors (GIST). To identify small molecule ligands which can specifically bind with the G-quadruplex (G4) in the c-KIT promoter region as potential antitumor agents, we propose the combination of electrospray ionization-mass spectrometry (ESI-MS), capillary electrophoresis frontal analysis (CE-FA), and Taylor dispersion analysis (TDA) to accurately investigate the G4/ligands binding properties. First, ESI-MS was used for initial screening of natural products (NPs).

View Article and Find Full Text PDF

The development of a weak anion micro-capillary film for protein chromatography.

J Chromatogr A

October 2016

Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, United Kingdom. Electronic address:

In this study, the surface of a microporous walled micro-capillary film (MMCF) was modified into a weak anion exchanger by coupling cyanuric chloride and 2-diethylaminoethylamine (DEAE) to the ethylene-vinyl alcohol (EVOH) matrix. Fourier transform infrared spectroscopy (FTIR) measurements of modified and unmodified MMCFs confirmed the addition of a triazine ring and DEAE onto the membrane. Binding of bovine serum albumin (BSA) at pH 7.

View Article and Find Full Text PDF

A fully integrated slidable and valveless microsystem, which performs solid phase DNA extraction (SPE), micro-polymerase chain reaction (μPCR) and micro-capillary electrophoresis (μCE) coupled with a portable genetic analyser, has been developed for forensic genotyping. The use of a slidable chip, in which a 1 μL-volume of the PCR chamber was patterned at the center, does not necessitate any microvalves and tubing systems for fluidic control. The functional micro-units of SPE, μPCR, and μCE were fabricated on a single glass wafer by conventional photolithography, and the integrated microdevice consists of three layers: from top to bottom, a slidable chip, a channel wafer in which a SPE chamber, a mixing microchannel, and a CE microchannel were fabricated, and a Ti/Pt resistance temperature detector (RTD) wafer.

View Article and Find Full Text PDF

Degradation of intestinal mRNA: a matter of treatment.

World J Gastroenterol

March 2015

Sabine Heumüller-Klug, Karin Kaiser, Elvira Wink, Cornelia Hagl, Lucas Wessel, Department of Pediatric Surgery Mannheim, Medical University of Heidelberg, 68167 Mannheim, Germany.

Aim: To characterize the influence of location, species and treatment upon RNA degradation in tissue samples from the gastrointestinal tract.

Methods: The intestinal samples were stored in different medium for different times under varying conditions: different species (human and rat), varying temperature (storage on crushed ice or room temperature), time point of dissection of the submucous-mucous layer from the smooth muscle (before or after storage), different rinsing methods (rinsing with Medium, PBS, RNALater or without rinsing at all) and different regions of the gut (proximal and distal small intestine, caecum, colon and rectum). The total RNA from different parts of the gut (rat: proximal and distal small intestine, caecum, colon and rectum, human: colon and rectum) and individual gut layers (muscle and submucosal/mucosal) was extracted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!