A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Forensic genetic analysis of nine miniSTR loci in the Korean population. | LitMetric

Nine miniSTR loci were analyzed in 191 unrelated individuals from Korea using three multiplex PCR systems (multiplex I: D1S1677, D2S441 and D4S2364; multiplex II: D10S1248, D14S1434 and D22S1045; multiplex III: D12S391, D16S3253 and D20S161). Due to the short PCR amplicons (< 145 bp), miniSTR systems can effectively be used in forensic analysis with highly degraded DNAs. Allele frequencies and forensic parameters were calculated to evaluate their usefulness in forensic casework. The Exact Test demonstrated that all loci surveyed here were found to be no deviation from Hardy-Weinberg equilibrium, except two miniSTR markers (D4S2364 and D16S3253). When we compared the distribution of genetic variation of six miniSTR markers (D1S1677, D2S441, D4S2364, D10S1248, D14S1434 and D22S1045), the Exact Test revealed significant differences (P < 0.05) between the Korean sample studied here and almost all of other samples of East Asian and European populations. The combined probability of match calculated from nine miniSTR loci was 1.28 x 10(-8), which is high degree of polymorphism. Thus, the miniSTR system, combined with other valuable miniSTR markers, may be suitable for recovering useful information in analyzing degraded DNA samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.legalmed.2009.03.012DOI Listing

Publication Analysis

Top Keywords

ministr loci
12
ministr markers
12
ministr
8
d1s1677 d2s441
8
d2s441 d4s2364
8
d10s1248 d14s1434
8
d14s1434 d22s1045
8
exact test
8
forensic
4
forensic genetic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!