A new configuration of C(18) thin film extraction phase designed for high sample throughput has been developed and applied to the analysis of benzodiazepines in spiked urine samples using high performance liquid chromatography coupled with tandem mass spectrometry. The high throughput analysis was achieved with the use of a robotic autosampler which enabled parallel analyte extraction in a 96-well plate format. Factors affecting data reproducibility, extraction kinetics, sample throughput, and reliability of the system were investigated and optimized. The intrawell reproducibility was 4.5-7.3%, while interwell reproducibility was 7.0-11% in urine and PBS samples. The limits of detection and quantitation were 0.05-0.15 ng/mL and 0.2-2.0 ng/mL for all analytes, respectively. By comparison with optimized automated multifiber SPME relying on rod geometry, the C(18) thin films showed higher extraction rates (approximate 2-fold increase) and hence higher sample throughput because of the improved configuration and more effective agitation/mass transfer. In addition, this new configuration provided an extraction phase with greater surface area to volume ratio and greater extraction phase volume, which resulted in approximately 2-fold increase in the extraction capacity for diazepam compared with the extractions with automated multifiber SPME rod geometry. The results of this investigation demonstrated the advantages of using thin films to improve extraction kinetics and sensitivity of automated SPME methods for high performance liquid chromatography.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac802524wDOI Listing

Publication Analysis

Top Keywords

extraction phase
16
sample throughput
12
c18 thin
8
extraction
8
high performance
8
performance liquid
8
liquid chromatography
8
extraction kinetics
8
automated multifiber
8
multifiber spme
8

Similar Publications

Introduction: Synthetic anabolic hormones, which may pose a potential risk to human health, should not be used in fattening food-producing animals. Because of the hormonal effects they cause, growth-promoting compounds are banned by legislation in the EU for use in animal husbandry. Consequently, all EU member states are required to conduct monitoring tests on the content and residues of these compounds in prescribed biological matrices to ensure the safety of food consumers.

View Article and Find Full Text PDF

Background: Software as a Medical Device (SaMD) and mobile health (mHealth) applications have revolutionized the healthcare landscape in the areas of remote patient monitoring (RPM) and digital therapeutics (DTx). These technological advancements offer a range of benefits, from improved patient engagement and real-time monitoring, to evidence-based personalized treatment plans, risk prediction, and enhanced clinical outcomes.

Objective: The systematic literature review aims to provide a comprehensive overview of the status of SaMD and mHealth apps, highlight the promising results, and discuss what is the potential of these technologies for improving health outcomes.

View Article and Find Full Text PDF

Vodobatinib is a Bcr-Abl 1 inhibitor, currently entering into Phase 2 clinical trials as a potential drug to treat glioblastoma patients. In the present work, a validated high-performance liquid chromatography (HPLC) detection method for the quantification of vodobatinib in rat plasma was established. Sample preparation involved liquid-liquid extraction method.

View Article and Find Full Text PDF

Purpose: Chronic jet lag (CJL) is known to disrupt circadian rhythms, which regulate various physiological processes, including ocular surface homeostasis. However, the specific effects of CJL on lacrimal gland function and the underlying cellular mechanisms remain poorly understood.

Methods: A CJL model was established using C57BL/6J mice.

View Article and Find Full Text PDF

A new analytical method was developed for the determination of 14 multiclass emerging organic contaminants in surface waters using LC-MS, and Dispersive Liquid-Liquid Microextraction (DLLME) for extraction. Different Natural Deep Eutectic Solvents (NADESs) composed of terpenes and organic acids were tested as extraction solvents and characterized by Fourier Transform Infrared Spectroscopy (FTIR), Hydrogen Nuclear Magnetic Resonance Spectroscopy (H-NMR), Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA), density, and viscosity, eliminating the need to use traditional chlorinated solvents. NADES produced with butyric acid and thymol showed the best results and was selected for application for the first time in the extraction of emerging organic contaminants of different classes in water samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!