The standard treatment technique used for whole-breast irradiation can result in undesirable dose distributions in the treatment site, leading to skin reaction/fibrosis and pulmonary and cardiac toxicities. Hence, the technique has evolved from conventional wedged technique (CWT) to segment intensity-modulated radiation therapy (SIMRT) and beamlet IMRT (IMRT). However, these newer techniques feature more highly modulated dose distributions that may be affected by respiration. The purpose of this work was to conduct a simple study of the clinical impact of respiratory motion on breast radiotherapy dose distributions for the three treatment planning techniques. The ultimate goal was to determine which patients would benefit most from the use of motion management. Eight patients with early-stage breast cancer underwent a free-breathing (FB) computed tomography (CT) simulation, with medial and lateral markers placed on the skin. Two additional CT scans were obtained at the end of inspiration (EI) and the end of expiration (EE). The FB-CT scan was used to develop treatment plans using each technique. Each plan was then applied to EI and EE-CT scans. Compared with the FB CT scan, the medial markers moved up to 1.8 cm in the anterior-superior direction at the end of inspiration (EI-scan), and on average 8 mm. The CWT and SIMRT techniques were not "sensitive" to respiratory motion, because the % clinical target volume (CTV) receiving 95% of the prescription dose (V(95%)) remained constant for both techniques. For patients that had large respiratory motion indicated by marker movement >0.6 cm, differences in coverage of the CTV at the V100% between FB and EI for beamlet IMRT plans were on the order of >10% and up to 18%. A linear model was developed to relate the dosimetric coverage difference introduced by respiration with the motion information. With this model, the dosimetric coverage difference introduced by respiratory motion could be evaluated during patient CT simulation. An appropriate treatment method can be chosen after the simulation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2008.07.002DOI Listing

Publication Analysis

Top Keywords

respiratory motion
20
dose distributions
16
motion breast
8
radiation therapy
8
beamlet imrt
8
dosimetric coverage
8
coverage difference
8
difference introduced
8
motion
7
respiratory
5

Similar Publications

Background: Respiratory motion during radiotherapy (RT) may reduce the therapeutic effect and increase the dose received by organs at risk. This can be addressed by real-time tracking, where respiration motion prediction is currently required to compensate for system latency in RT systems. Notably, for the prediction of future images in image-guided adaptive RT systems, the use of deep learning has been considered.

View Article and Find Full Text PDF

Impact of diaphragm motion on dosimetry in lower thoracic spine stereotactic body radiotherapy.

Phys Med

January 2025

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.

Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.

Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.

View Article and Find Full Text PDF

Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia.

Radiat Oncol J

December 2024

Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.

Purpose: Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.

View Article and Find Full Text PDF

Acute simulated weight gain might not increase the energy cost of walking in adolescents with obesity.

Pediatr Obes

December 2024

Laboratory of the Metabolic Adaptations to Exercise under Physiological and Pathological Conditions (AME2P), Clermont Auvergne University, Clermont-Ferrand, France.

Introduction: This work aims at evaluating the adaptations of the energy cost of walking (Cw) to simulated weight gain at different walking speeds in adolescents with obesity.

Methods: Substrate use and Cw were evaluated during a graded walking exercise (4 × 5min at 0.75, 1, 1.

View Article and Find Full Text PDF

The global rise in work-related musculoskeletal ailments has led to issues like neck discomfort, scapular muscle dysfunction, reduced neck mobility, and functional limitations. This study aimed to evaluate the effectiveness of scapular functional exercises (SFE) and cervical isometric exercises (CIE) on pain, cervical range of motion (CROM), and functional limitations in individuals with chronic mechanical neck pain (CMNP). A two-arm, parallel group pretest-post-test randomized comparative trial was conducted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!