A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Circulating methylated SEPT9 DNA in plasma is a biomarker for colorectal cancer. | LitMetric

Background: The presence of aberrantly methylated SEPT9 DNA in plasma is highly correlated with the occurrence of colorectal cancer. We report the development of a new SEPT9 biomarker assay and its validation in case-control studies. The development of such a minimally invasive blood-based test may help to reduce the current gap in screening coverage.

Methods: A new SEPT9 DNA methylation assay was developed for plasma. The assay comprised plasma DNA extraction, bisulfite conversion of DNA, purification of bisulfite-converted DNA, quantification of converted DNA by real-time PCR, and measurement of SEPT9 methylation by real-time PCR. Performance of the SEPT9 assay was established in a study of 97 cases with verified colorectal cancer and 172 healthy controls as verified by colonoscopy. Performance based on predetermined algorithms was validated in an independent blinded study with 90 cases and 155 controls.

Results: The SEPT9 assay workflow yielded 1.9 microg/L (CI 1.3-3.0) circulating plasma DNA following bisulfite conversion, a recovery of 45%-50% of genomic DNA, similar to yields in previous studies. The SEPT9 assay successfully identified 72% of cancers at a specificity of 93% in the training study and 68% of cancers at a specificity of 89% in the testing study.

Conclusions: Circulating methylated SEPT9 DNA, as measured in the new (m)SEPT9 assay, is a valuable biomarker for minimally invasive detection of colorectal cancer. The new assay is amenable to automation and standardized use in the clinical laboratory.

Download full-text PDF

Source
http://dx.doi.org/10.1373/clinchem.2008.115808DOI Listing

Publication Analysis

Top Keywords

sept9 dna
16
colorectal cancer
16
methylated sept9
12
sept9 assay
12
dna
10
sept9
9
circulating methylated
8
dna plasma
8
assay
8
minimally invasive
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!