A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental evaluation of a new articulated Amplatzer ductal occluder device without fabric. | LitMetric

Experimental evaluation of a new articulated Amplatzer ductal occluder device without fabric.

Catheter Cardiovasc Interv

University of Minnesota Children's Hospital, Fairview, Pediatric Cardiology, MMC 94, 420 Delaware St. SE, Minneapolis, Minnesota 55455, USA.

Published: September 2009

Objectives: To describe a new percutaneous PDA device.

Background: The ADO II was developed by AGA Medical for closure of small-moderate sized PDAs via a small delivery catheter from an antegrade or retrograde catheter approach. The objective of this study was to evaluate the technical feasibility, safety, and efficacy of the ADO II in a canine PDA model.

Methods: The ADO-II consists of multi-layer nitinol wire braid with symmetric retention disks and an articulating connecting center waist, without sewn-in polyester, that can be delivered though a 4-5F catheter. A PDA was surgically created in nine dogs. Transcatheter occlusion of the PDA was performed using the ADO II. Angiographic and hemodynamic data were obtained at 7, 30, 60, and 90 days post-procedure. The devices were then harvested for pathology.

Results: Devices were placed transarterially (n = 8) and transvenously (n = 1). All PDAs were occluded and there were no significant pressure gradients (P > 0.05) at the immediate and 90 post-implant evaluations. Pathology found endothelial coverage on all aortic and pulmonary disks, except at the tip of the microscrew. There were no procedural complications. One canine was euthanized 4 hr after device implant because of a clinical deterioration. The staff veterinarian and pathologist concluded that the animal's illness was not device related.

Conclusions: The Amplatzer ADO II devices can be safely deployed in animal models of PDAs, with complete resolution of the PDA shunt. The lower profile and symmetry of the ADO II allows for venous or arterial approach and smaller delivery catheter size. The ADO-II is expected to be a preferred alternative for closure of small-moderate PDAs.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.22059DOI Listing

Publication Analysis

Top Keywords

closure small-moderate
8
delivery catheter
8
pda
5
ado
5
experimental evaluation
4
evaluation articulated
4
articulated amplatzer
4
amplatzer ductal
4
ductal occluder
4
occluder device
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!