Objective: The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy.
Methods: Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler.
Results: 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%).
Conclusion: Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/uog.6372 | DOI Listing |
Front Vet Sci
December 2024
Department of Cardiology, Uenonomori Animal Hospital, Tokyo, Japan.
Objectives: Surgical options for mitral valve repair in dogs are unstandardized and influenced by various factors. This study describes a four-point surgical technique (MI-4) to reduce mitral regurgitation and provides data from a study of dogs with 12 months of follow up.
Methods: Twenty-five dogs with stages C or D mitral insufficiency were treated by one of two surgeons using the MI-4 procedure at Ueno no Mori Animal Hospital between October 2021 and May 2023.
Am J Cardiovasc Drugs
December 2024
Cardiology A Department, Research Laboratory LR12 SP 16 Fattouma Bourguiba University Hospital, University of Monastir, Monastir University, Rue du 1er juin 1955, 5000, Monastir, Tunisia.
Unlabelled: BACKGROUND AND OBJECTIVE: Left atrial strain (LAS) has prognostic value in patients with atrial fibrillation (AF). Consequently, therapies that improve LAS may help reduce AF-related adverse cardiac events. We aimed to compare how digoxin and bisoprolol modulate LAS in patients with AF being treated with rate control.
View Article and Find Full Text PDFBirth Defects Res
December 2024
Department of Ultrasound Diagnosis, the Second Xiangya Hospital, Central South University, Changsha, China.
Aim: This study investigated the major factors contributing to the missed diagnosis of total anomalous pulmonary venous connection (TAPVC) in fetal echocardiography.
Methods: We retrospectively analyzed the prenatal ultrasonic images of 32 fetuses with missed diagnoses of TAPVC, compared them with autopsy and postnatal surgical records, and summarized the most likely reasons leading to the missed diagnoses.
Results: We studied a total of 157 fetuses with TAPVC, 32 (20.
Diagnostics (Basel)
December 2024
Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China.
The automatic left ventricle segmentation in transesophageal echocardiography (TEE) is of significant importance. In this paper, we constructed a large-scale TEE apical four-chamber view (A4CV) image dataset and proposed an automatic left ventricular segmentation method for the TEE A4CV based on the UNeXt deep neural network. UNeXt, a variant of U-Net integrating a multilayer perceptron, was employed for left ventricle segmentation in the TEE A4CV because it could yield promising segmentation performance while reducing both the number of network parameters and computational complexity.
View Article and Find Full Text PDFJ Vet Cardiol
November 2024
James L. Voss Veterinary Teaching Hospital, College of Veterinary Medicine & Biomedical Sciences, Colorado State University, Fort Collins, CO, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!