Objective: C2 translaminar (TL) screws rigidly capture the posterior elements of C2, avoid risk of vertebral artery injury, and are less technically demanding than C2 pedicle (PD) screws. However, a C2-TL screw breach places the spinal cord at risk, and the durability of C2-TL screws remains unknown. It is unclear if TL versus PD screw fixation of C2 is truly associated with less operative morbidity, greater accuracy of screw placement, or equivalent durability.
Methods: We retrospectively reviewed the records of 167 consecutive patients undergoing posterior cervical fusion with either PD or TL screw fixation of C2. Perioperative morbidity, breach of the C2 lamina or pedicle on postoperative computed tomographic scans, and rates of operative revision were compared between PD and TL screw constructs in axial (C1-C2 or C1-C3) and subaxial (C2 and caudal) cervical fusions.
Results: In total, 152 C2-TL screws and 161 C2-PD screws were placed in 167 patients. Thirty-one (19%) cases of axial cervical fusion (C1-C2 or C1-C3) were performed (mean age, 63.8 +/- 20.6 years) with either C2-TL (16 [52%]) or C2-PD (15 [48%]) screw fixation. One hundred thirty-six (81%) cases of subaxial cervical fusion (C2-caudal) were performed (mean age, 57.9 +/- 14.7 years) with either C2-TL (66 [49%]) or C2-PD (70 [51%]) screw fixation. For both axial and subaxial cervical fusions, baseline patient characteristics and all measures of perioperative morbidity were similar between C2-TL and C2-PD screw cohorts. In total, 11 (7%) PD screws breached the pedicle (0 requiring acute revision) versus only 2 (1.3%) TL screws that breached the C2 lamina (1 requiring acute revision) (P = 0.018). By 1 year postoperatively, pseudoarthrosis or screw pullout requiring reoperation was required in 4 (6.1%) patients with C2-TL screws versus 0 (0%) patients with PD screws (P < 0.05 for subaxial constructs). No cases of C2-TL or C2-PD axial fusion required reoperation or screw pullout or pseudoarthrosis.
Conclusion: In our experience, radiographic breach of C2 pedicle screws occurred more frequently than C2 laminar screw breach. However, this was not associated with an increase in morbidity. By 12 months postoperatively, C2-TL screws were associated with a greater incidence of operative revision when used in subaxial constructs but similarly effective for axial cervical constructs. The 1-year durability of C2-TL screws might be inferior to C2 pedicle screws for subaxial fusions, but equally effective for axial cervical fusions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1227/01.NEU.0000338955.36649.4F | DOI Listing |
Hand Surg Rehabil
December 2024
Department of Hand Surgery, Grenoble Alpes University Hospital, 38000 Grenoble, France; TIMC Laboratory, Grenoble Alpes University, Pavillon Taillefer, 38700 La Tronche, France. Electronic address:
New surgical techniques for the treatment of scaphoid non-union, developed in the last two decades, now enable a healing rate of 80-90%. However, no consensus exists for the surgical treatment of non-union. On the other hand, regenerative medicine techniques have enriched the therapeutic armamentarium for non-union, especially in the lower limbs, with the use of autologous concentrated bone marrow injection using autologous osteogenic precursors to create a favorable microenvironment for bone healing.
View Article and Find Full Text PDFPatient Saf Surg
December 2024
Department of Trauma Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich, 8091, Switzerland.
Background: Hemodynamically unstable pelvic ring fractures from high-energy trauma are critical injuries in trauma care, requiring urgent intervention and precise diagnostics. With ongoing advancements in trauma management, treatment strategies have evolved, with some techniques becoming obsolete as new ones emerge. This study aimed to evaluate changes and trends in treatment algorithms for these injuries over approximately 40 years.
View Article and Find Full Text PDFJ Bone Joint Surg Am
October 2024
Musculoskeletal Tumor Center, Department of Orthopedics, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, People's Republic of China.
Background: Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.
View Article and Find Full Text PDFJ Neurosurg Spine
December 2024
1Department of Orthopaedic Surgery, The Och Spine Hospital/Columbia University Irving Medical Center, New York, New York.
Objective: The objective of this study was to compare a multiple pelvic screw fixation strategy (dual bilateral 4 pelvic screw fixation [4PvS]) with the use of single bilateral 2 pelvic screw fixation (2PvS), with the aim of addressing lumbosacral junction stability.
Methods: This analysis is a single-center, retrospective review of ASD patients treated between 2015 and 2021. All patients had a minimum 2-year follow-up and spinal fusion to the sacrum without sacroiliac fusion and met at least one radiographic and procedural criterion: pelvic incidence-lumbar lordosis ≥ 20°, T1 pelvic angle ≥ 20°, sagittal vertical axis ≥ 7.
Background: Achieving bony union in scaphoid nonunion fractures is challenging. Various bone grafts have been studied using headless compression screws (HCS) fixation. However, the impact of bone graft choice on bone healing with volar locking plates (VLP) use is less clear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!