Background: Noninvasive detection of innate immune function such as the accumulation of neutrophils remains a challenge in many areas of clinical medicine. We hypothesized that granulocytes could generate volatile organic compounds.

Methods: To begin to test this, we developed a bioreactor and analytical GC-MS system to accurately identify and quantify gases in trace concentrations (parts per billion) emitted solely from cell/media culture. A human promyelocytic leukemia cell line, HL60, frequently used to assess neutrophil function, was grown in serum-free medium.

Results: HL60 cells released acetaldehyde and hexanaldehyde in a time-dependent manner. The mean +/- SD concentration of acetaldehyde in the headspace above the cultured cells following 4-, 24- and 48-h incubation was 157 +/- 13 ppbv, 490 +/- 99 ppbv, 698 +/- 87 ppbv. For hexanaldehyde these values were 1 +/- 0.3 ppbv, 8 +/- 2 ppbv, and 11 +/- 2 ppbv. In addition, our experimental system permitted us to identify confounding trace gas contaminants such as styrene.

Conclusion: This study demonstrates that human immune cells known to mimic the function of innate immune cells, like neutrophils, produce volatile gases that can be measured in vitro in trace amounts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2683805PMC
http://dx.doi.org/10.1186/1479-5876-7-31DOI Listing

Publication Analysis

Top Keywords

+/- ppbv
24
acetaldehyde hexanaldehyde
8
innate immune
8
ppbv +/-
8
immune cells
8
+/-
7
ppbv
6
cells
5
hexanaldehyde cultured
4
cultured white
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!