Evaluation for a ventricular assist device: selecting the appropriate candidate.

Circulation

Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.

Published: April 2009

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.109.850610DOI Listing

Publication Analysis

Top Keywords

evaluation ventricular
4
ventricular assist
4
assist device
4
device selecting
4
selecting appropriate
4
appropriate candidate
4
evaluation
1
assist
1
device
1
selecting
1

Similar Publications

Objective: To investigate the effects and mechanisms of miRNA 221 on myocardial ischemia/reperfusion injury (MIRI) in mice through the regulation of phospholamban (PLB) expression.

Methods: The MIRI mouse model was created and mice were divided into sham, MIRI, MIRI+ 221, and MIRI+ scr groups, with miRNA 221 overexpression induced in the myocardium of MIRI mice by targeted myocardial injection. Quantitative RT-PCR analysis was performed to observe the variation in miRNA 221, PLB, SERCA2, RYR2, NCX1, Cyt C and caspase 3 mRNA levels in myocardium, while Western blot assessed the levels of PLB, p-PLB (Ser16), p-PLB (Thr17), SERCA2, RYR2, NCX1, Cyt C and caspase 3 proteins.

View Article and Find Full Text PDF

Background: Implantable cardioverter-defibrillators (ICDs) are essential for reducing sudden cardiac death in patients at risk of ventricular arrhythmias. The choice of ICD lead - single-coil or dual-coil - can influence device performance and patient outcomes. This meta-analysis evaluates the comparative efficacy and safety of single-coil versus dual-coil ICD leads to inform clinical decision-making.

View Article and Find Full Text PDF

Systemic venous collaterals between Glenn and Fontan: prevalence, therapy, and impact on outcomes.

Cardiol Young

January 2025

Department of Congenital and Pediatric Heart Surgery, German Heart Center Munich, Technische Universität München, Division of Congenital and Pediatric Heart Surgery, University Hospital of Munich, Ludwig-Maximilians-Universität München, Europäisches Kinderherzzentrum München, Munich, Germany.

Objective: This study aimed to evaluate veno-venous collaterals between bidirectional cavopulmonary shunt and total cavopulmonary connection.

Methods: Patients who underwent staged total cavopulmonary connection between 1995 and 2022 were reviewed. Veno-venous collaterals between bidirectional cavopulmonary shunt and total cavopulmonary connection were depicted using angiograms.

View Article and Find Full Text PDF

Background: Objective indices of functional capacity in patients with diabetic cardiomyopathy and stage B heart failure (HF) have not been comprehensively defined. We sought to characterize the cardiopulmonary exercise characteristics of individuals with diabetic cardiomyopathy at high risk for overt HF.

Methods: The relationships from cardiopulmonary exercise testing with clinical and laboratory characteristics of participants with diabetic cardiomyopathy were evaluated using baseline data from the ARISE-HF trial (Aldose Reductase Inhibition for Stabilization of Exercise Capacity in Heart Failure).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!