In this study, we perform a comparative study of independent component analysis (ICA) and conventional filtering (CF) for the purpose of artifact reduction from simultaneous gastric EMG and magnetogastrography (MGG). EMG/MGG data were acquired from ten anesthetized pigs by obtaining simultaneous recordings using serosal electrodes (EMG) as well as with a superconducting quantum interference device biomagnetometer (MGG). The analysis of MGG waveforms using ICA and CF indicates that ICA is superior to the CF method in its ability to extract respiration and cardiac artifacts from MGG recordings. A signal frequency analysis of ICA- and CF-processed data was also undertaken using waterfall plots, and it was determined that the two methods produce qualitatively comparable results. Through the use of simultaneous EMG/MGG, we were able to demonstrate the accuracy and trustworthiness of our results by comparison and cross-validation within the framework of a porcine model.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2855971PMC
http://dx.doi.org/10.1109/TBME.2009.2020694DOI Listing

Publication Analysis

Top Keywords

conventional filtering
8
independent component
8
component analysis
8
artifact reduction
8
reduction simultaneous
8
simultaneous gastric
8
gastric emg
8
emg magnetogastrography
8
comparison conventional
4
filtering independent
4

Similar Publications

Direct Frequency Comb Cavity Ring-Down Spectroscopy Using Vernier Filtering.

J Phys Chem A

January 2025

Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, United States.

We present direct frequency comb cavity ring-down spectroscopy with Vernier filtering as a straightforward approach to sensitive and multiplexed trace gas detection. The high finesse cavity acts both to extend the interaction length with the sample and as a spectral filter, alleviating the need for dispersive elements or an interferometer. In this demonstration, a free running interband cascade laser was used to generate a comb centered at 3.

View Article and Find Full Text PDF

Double bowtie design for high sensitivity pediatric spectral CT.

Conf Proc Int Conf Image Form Xray Comput Tomogr

August 2024

Department of Radiology, Perelman School of Medicine, Philadelphia, PA USA.

Despite the evident benefits of spectral computed tomography (CT) in delivering qualitative imaging superior to that of conventional CT in adults, its application in pediatric diagnostic imaging is still relatively limited due to various reasons, including design limitations and radiation dose considerations. The use of specialized K-edge filters, in conjunction with other spectral technologies, has been demonstrated to improve spectral quantification accuracy. X-ray flux limitations generally pose challenges in these concepts when applied to adults.

View Article and Find Full Text PDF

Identifying the compound formulae-related xenobiotics in bio-samples is full of challenges. Conventional strategies always exhibit the insufficiencies in overall coverage, analytical efficiency, and degree of automation, and the results highly rely on the personal knowledge and experience. The goal of this work was to establish a software-aided approach, by integrating ultra-high performance liquid chromatography/ion-mobility quadrupole time-of-flight mass spectrometry (UHPLC/IM-QTOF-MS) and in-house high-definition MS library, to enhance the identification of prototypes and metabolites of the compound formulae , taking Sishen formula (SSF) as a template.

View Article and Find Full Text PDF

Deep learning methods have significantly improved medical image analysis, particularly in detecting COVID-19 chest X-rays. Nonetheless, these methodologies frequently inhibit some drawbacks, such as limited interpretability, extensive computational resources, and the need for extensive datasets. To tackle these issues, we introduced two novel algorithms: the Dynamic Co-Occurrence Grey Level Matrix (DC-GLM) and the Contextual Adaptation Multiscale Gabor Network (CAMSGNeT).

View Article and Find Full Text PDF

Nanosecond Molecular Motion in pHP1α Liquid-Liquid Phase Separation Captured by Solid-State NMR.

J Phys Chem Lett

January 2025

Centre of High Field NMR Spectroscopy and Imaging, Nanyang Technological University, 21 Nanyang Link, Singapore 637371.

The relationship among protein structure, function, and dynamics is fundamental to biological activity, particularly in more complex biomolecular systems. Solid-state and solution-state NMR techniques offer powerful means to probe these dynamics across various time scales. However, standard assumptions about molecular motion are often challenged in phase-separated systems like phosphorylated heterochromatin protein 1 alpha (pHP1α), which exhibit both solid- and solution-like characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!