An investigation of the hypoalgesic effects of TENS delivered by a glove electrode.

J Pain

Health and Rehabilitation Sciences Research Institute, University of Ulster, Ulster, UK; School of Health Sciences, University of Ulster, Ulster, UK.

Published: July 2009

Unlabelled: This randomized, placebo-controlled, blinded study investigated the hypoalgesic effects of high-frequency transcutaneous electrical nerve stimulation (TENS) delivered via a glove electrode compared with standard self-adhesive electrodes. Fifty-six TENS-naïve, healthy individuals (18 to 50 years old; 28 men, 28 women) were randomly allocated to 1 of 4 groups (n = 14 per group): glove electrode; placebo TENS using a glove electrode; standard electrode; and no treatment control. Active TENS (continuous stimulus, 100 Hz, strong but comfortable intensity) was applied to the dominant forearm/hand for 30 minutes. Placebo TENS was applied using a burst stimulus, 100-Hz frequency, 5-second cycle time for 42 seconds, after which the current amplitude was automatically reset to 0 mA. Pressure pain thresholds (PPTs) were recorded from 3 points on the dominant and nondominant upper limbs before and after TENS. Statistical analyses of dominant PPT data using between-within groups ANOVA showed significant differences between groups at all 3 recording points (P = .01). Post hoc Scheffe tests indicated no significant difference between the standard electrode and glove electrode groups. There was a significant hypoalgesic effect in the standard electrode group compared with the control group and between the glove electrode group and both the control and placebo TENS groups. There was no significant interactive effect between time and group at any of the recording points (P > .05).

Perspective: This study presents a comparison of the hypoalgesic effects of 2 different types of TENS electrode, a novel glove electrode and standard self-adhesive rectangular electrodes. The glove electrode provides a larger contact area with the skin, thereby stimulating a greater number of nerve fibers. The results show that both electrodes have similar hypoalgesic effects and therefore give the clinician another choice in electrode.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2761234PMC
http://dx.doi.org/10.1016/j.jpain.2008.12.004DOI Listing

Publication Analysis

Top Keywords

glove electrode
32
hypoalgesic effects
16
electrode
13
placebo tens
12
standard electrode
12
tens
8
tens delivered
8
glove
8
delivered glove
8
standard self-adhesive
8

Similar Publications

Flat-Knitted Double-Tube Structure Capacitive Pressure Sensors Integrated into Fingertips of Fully Fashioned Glove Intended for Therapeutic Use.

Sensors (Basel)

November 2024

Institute for Textile Machinery and High Performance Material Technology (ITM), Faculty for Mechanical Science and Engineering, Technische Universität Dresden, 01062 Dresden, Germany.

A therapeutic glove, which enables medical non-professionals to perform physiotherapeutic gripping and holding movements on patients, would significantly improve the healthcare situation in physiotherapy. The glove aims to detect the orthogonal pressure load and provide feedback to the user. The use of textile materials for the glove assures comfort and a good fit for the user.

View Article and Find Full Text PDF

An electrochemical biosensor for on-glove application: Organophosphorus pesticide detection directly on fruit peels.

Talanta

February 2025

Department of Pharmacy, University of Naples 'Federico II', Via D. Montesano 49, 80131, Naples, Italy; BAT Center-Interuniversity Center for Studies on Bioinspired Agro-Environmental Technology, University of Napoli Federico II, 80055, Naples, Italy; Bioelectronics Task Force at University of Naples Federico II, Italy. Electronic address:

One of the greatest challenges for the future is represented by the conservation of global agricultural production: it is necessary to implement early monitoring of the health conditions of crops through innovative technologies that allow a sustainable development. To reach this goal, the development of portable biosensors might represent a robust strategy for monitoring agricultural sites in agreement with the requirement of precision agriculture. In this work, an electrochemical inhibition biosensor has been engineered onto a glove to quantify organophosphorus pesticides directly on fruits peels.

View Article and Find Full Text PDF

Integrated scanning electrochemical cell microscopy platform with local electrochemical impedance spectroscopy using a preamplifier.

Faraday Discuss

October 2024

State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu, 210023, P. R. China.

Local electrochemical impedance spectroscopy (LEIS) has emerged as a technique to characterize local electrochemical processes on heterogeneous surfaces. However, current LEIS heavily relies on lock-in amplifiers that have a poor gain effect for weak currents, limiting the achievements of high-spatial imaging. Herein, an integrated scanning electrochemical cell microscopy is developed by directly collecting the alternating current (AC) signal through a preamplifier.

View Article and Find Full Text PDF

MXene-Fiber Composite Membranes for Permeable and Biocompatible Skin-Interfaced Iontronic Mechanosensing.

Nano Lett

October 2024

Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.

Article Synopsis
  • Researchers developed a new skin-interfaced iontronic mechanosensing (SIIM) system that mimics human skin's sensory functions using natural materials and porous composites to improve biocompatibility and comfort.
  • The SIIM architecture showcases outstanding pressure sensitivity, low detection limits, and stability, while also allowing for sweat permeability, making it suitable for long-term wear.
  • This innovative sensor can be integrated into wearable devices like smart gloves to accurately monitor human movements, highlighting its potential for various applications in the wearable tech industry.
View Article and Find Full Text PDF

High-density electromyography (HD-EMG) can provide a natural interface to enhance human-computer interaction (HCI). This study aims to demonstrate the capability of a novel HD-EMG forearm sleeve equipped with up to 150 electrodes to capture high-resolution muscle activity, decode complex hand gestures, and estimate continuous hand position via joint angle predictions. Ten able-bodied participants performed 37 hand movements and grasps while EMG was recorded using the HD-EMG sleeve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?