Unlabelled: This randomized, placebo-controlled, blinded study investigated the hypoalgesic effects of high-frequency transcutaneous electrical nerve stimulation (TENS) delivered via a glove electrode compared with standard self-adhesive electrodes. Fifty-six TENS-naïve, healthy individuals (18 to 50 years old; 28 men, 28 women) were randomly allocated to 1 of 4 groups (n = 14 per group): glove electrode; placebo TENS using a glove electrode; standard electrode; and no treatment control. Active TENS (continuous stimulus, 100 Hz, strong but comfortable intensity) was applied to the dominant forearm/hand for 30 minutes. Placebo TENS was applied using a burst stimulus, 100-Hz frequency, 5-second cycle time for 42 seconds, after which the current amplitude was automatically reset to 0 mA. Pressure pain thresholds (PPTs) were recorded from 3 points on the dominant and nondominant upper limbs before and after TENS. Statistical analyses of dominant PPT data using between-within groups ANOVA showed significant differences between groups at all 3 recording points (P = .01). Post hoc Scheffe tests indicated no significant difference between the standard electrode and glove electrode groups. There was a significant hypoalgesic effect in the standard electrode group compared with the control group and between the glove electrode group and both the control and placebo TENS groups. There was no significant interactive effect between time and group at any of the recording points (P > .05).
Perspective: This study presents a comparison of the hypoalgesic effects of 2 different types of TENS electrode, a novel glove electrode and standard self-adhesive rectangular electrodes. The glove electrode provides a larger contact area with the skin, thereby stimulating a greater number of nerve fibers. The results show that both electrodes have similar hypoalgesic effects and therefore give the clinician another choice in electrode.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2761234 | PMC |
http://dx.doi.org/10.1016/j.jpain.2008.12.004 | DOI Listing |
Sensors (Basel)
November 2024
Institute for Textile Machinery and High Performance Material Technology (ITM), Faculty for Mechanical Science and Engineering, Technische Universität Dresden, 01062 Dresden, Germany.
A therapeutic glove, which enables medical non-professionals to perform physiotherapeutic gripping and holding movements on patients, would significantly improve the healthcare situation in physiotherapy. The glove aims to detect the orthogonal pressure load and provide feedback to the user. The use of textile materials for the glove assures comfort and a good fit for the user.
View Article and Find Full Text PDFTalanta
February 2025
Department of Pharmacy, University of Naples 'Federico II', Via D. Montesano 49, 80131, Naples, Italy; BAT Center-Interuniversity Center for Studies on Bioinspired Agro-Environmental Technology, University of Napoli Federico II, 80055, Naples, Italy; Bioelectronics Task Force at University of Naples Federico II, Italy. Electronic address:
One of the greatest challenges for the future is represented by the conservation of global agricultural production: it is necessary to implement early monitoring of the health conditions of crops through innovative technologies that allow a sustainable development. To reach this goal, the development of portable biosensors might represent a robust strategy for monitoring agricultural sites in agreement with the requirement of precision agriculture. In this work, an electrochemical inhibition biosensor has been engineered onto a glove to quantify organophosphorus pesticides directly on fruits peels.
View Article and Find Full Text PDFFaraday Discuss
October 2024
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu, 210023, P. R. China.
Local electrochemical impedance spectroscopy (LEIS) has emerged as a technique to characterize local electrochemical processes on heterogeneous surfaces. However, current LEIS heavily relies on lock-in amplifiers that have a poor gain effect for weak currents, limiting the achievements of high-spatial imaging. Herein, an integrated scanning electrochemical cell microscopy is developed by directly collecting the alternating current (AC) signal through a preamplifier.
View Article and Find Full Text PDFNano Lett
October 2024
Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
Sci Rep
August 2024
Battelle Memorial Institute, Neurotechnology, Columbus, OH, USA.
High-density electromyography (HD-EMG) can provide a natural interface to enhance human-computer interaction (HCI). This study aims to demonstrate the capability of a novel HD-EMG forearm sleeve equipped with up to 150 electrodes to capture high-resolution muscle activity, decode complex hand gestures, and estimate continuous hand position via joint angle predictions. Ten able-bodied participants performed 37 hand movements and grasps while EMG was recorded using the HD-EMG sleeve.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!