Objective: To investigate the expression of matrix metalloproteinase-3 after brain contusion and its applicability for estimating the age of brain contusion.
Methods: Rats had been divided into three groups: control group, sham operation group and brain contusion group. The expression of matrix metalloproteinase-3 at different time was detected by immunohistochemistry and Western blot.
Results: By the immunohistochemistry, no staining was observed in control and sham operation groups. The positive staining of MMP-3 appeared 6 hours after contusion, increased gradually in 24 hours and peaked 5 days after contusion, then started to decrease, 14 days after contusion still could be observed. By the Western blot analysis, no expression of MMP-3 was detected in control and sham groups. The positive staining of MMP-3 appeared 6 hours after contusion, increased gradually and maximized 5 days after contusion, then started to decrease, 14 days after contusion still could be found.
Conclusion: Time-order expression of MMP-3 could be used for estimating the age of brain contusion in forensic pathology.
Download full-text PDF |
Source |
---|
Radiol Bras
January 2025
Escola de Medicina - Universidade de Passo Fundo (UPF), Passo Fundo, RS, Brazil.
Objective: To identify and analyze the main findings on computed tomography (CT) scans ordered in the emergency department of a tertiary care hospital.
Materials And Methods: This was a cross-sectional observational study conducted through analysis of CT scans of the head, chest, and abdomen of all patients admitted to the emergency department of a tertiary care hospital over a period of four months.
Results: Among a sample of 331 patients, pathological radiological findings were observed in 59.
Am J Transl Res
December 2024
Department of Neurosurgery, The First Medical Center of Chinese PLA General Hospital Beijing, China.
Objective: To identify risk factors associated with progressive hemorrhagic injury (PHI) in patients with isolated traumatic brain injury (TBI) and to develop prognostic models for predicting patient outcomes.
Methods: A total of 137 patients with isolated TBI who underwent additional CT scans were included in the retrospective study. Single-factor analysis and multivariate logistic regression analysis were performed to identify significant risk factors associated with PHI development.
J Clin Neurosci
January 2025
Department of Neurosurgery, Shaare Zedek Medical Center, Jerusalem, Israel.
Decompressive craniectomy is a procedure for managing elevated intracranial pressure (ICP). However, it carries a high morbidity and mortality toll. While there is relative consensus regarding the bony part of the decompression, the role of dura opening and the optimal technique to perform it are under debate.
View Article and Find Full Text PDFBrain Res Bull
January 2025
Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University - Yifu Science Hall, 37 Xueyuan Road, Haidian, Beijing 100191, China. Electronic address:
Quantifying axons and myelin is essential for understanding spinal cord injury (SCI) mechanisms and developing targeted therapies. This study proposes and validates an automated method to measure axons and myelin, applied to compare contusion, dislocation, and distraction SCIs in a rat model. Spinal cords were processed and stained for neurofilament, tubulin, and myelin basic protein, with histology images segmented into dorsal, lateral, and ventral white matter regions.
View Article and Find Full Text PDFSurg Neurol Int
December 2024
Department of Neurosurgery, University of California, Irvine, Orange, United States.
Background: Stereoelectroencephalography (SEEG) is a common diagnostic surgical procedure for patients with medically refractory epilepsy. We aimed to describe our initial experience with the recently released NeuroOne Evo SEEG electrode product (Zimmer Biomet, Warsaw, IN) and review technical specifications for other currently approved depth SEEG electrodes.
Methods: We performed a record review on the first five patients implanted with NeuroOne Evo SEEG electrode product using the robotic stereotactic assistance robot platform and described our surgical technique in detail.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!