Unlabelled: This study aims to describe the first clinical results in the treatment of dislocated olecranon fractures with 2.2-mm, fine-threaded wires with a washer. Furthermore, in the second part of the article, the stability of these new implants has been compared to standard tension band wiring in a sawbone model.

Patients: The radiological and clinical outcomes in 24 patients (mean age: 53.6 years) with 24 isolated Mayo type I and II fractures of the olecranon were evaluated in a prospective study after open reduction and internal fixation (ORIF) with a new fixation device (FFS; Orthofix). The quality of reduction with the implementation of 24 FFS constructions was compared with 24 tension band-wiring procedures performed by six different surgeons in a standard sawbone Mayo type IIa fracture model. Stability was tested in all constructs using a single cycle load to failure protocol (group I), cyclic loading for 300 cycles between 10 and 500 N (group II) and incremental sinusoidal loading from 10 to 200 N with an incremental increase of 10 N per cycle (group III) in a laboratory study.

Results: The Morrey elbow score was excellent in 23 patients and good in one patient, with mean DASH score of 1.6. No implant migration, secondary dislocation or nonunion was observed. In the sawbone model, the quality of reduction was the same with the FFS implants compared to the tension band wiring in the sawbone model. Here, bending moments in all three groups showed no significant difference, whereas displacement at failure was significantly greater in the tension band-wiring group at a single cycle load (p=0.017).

Conclusion: Clinical results were comparable to tension band wiring and stability of the implants in the sawbone model was the same; thus, we conclude that the FFS technique can serve as an alternative treatment option for isolated olecranon fractures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2009.01.129DOI Listing

Publication Analysis

Top Keywords

tension band
12
band wiring
12
sawbone model
12
olecranon fractures
8
stability implants
8
implants compared
8
wiring sawbone
8
mayo type
8
quality reduction
8
compared tension
8

Similar Publications

Objective: To analyze the effectiveness of three internal fixation methods, namely hollow screw combined with Kirschner wire tension band, hollow screw combined with anchor nail, and modified 1/3 tubular steel plate, in the treatment of avulsion fracture of tibial tubercle (AFTT) in adolescents.

Methods: Between January 2018 and September 2023, 19 adolescent AFTT patients who met the selection criteria were admitted. According to different internal fixation methods, patients were divided into group A (8 cases, hollow screw combined with Kirschner wire tension band), group B (6 cases, hollow screw combined with anchor nail), and group C (5 cases, modified 1/3 tubular steel plate).

View Article and Find Full Text PDF

Objective: To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.

Methods: A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B).

View Article and Find Full Text PDF

Preparation of Hydroxyapatite-Aligned Collagen Sheets and Their Evaluation for Fibroblast Adhesion and Collagen Secretion.

ACS Biomater Sci Eng

January 2025

Department of Materials Science and Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550, Japan.

The structure of many native tissues consists of aligned collagen (Col) fibrils, some of which are further composited with dispersed hydroxyapatite (HAp) nanocrystals. Accurately mimicking this inherent structure is a promising approach to enhance scaffold biocompatibility in tissue engineering. In this study, biomimetic sheets composed of highly aligned Col fibrils were fabricated using a plastic compression and tension method, followed by the deposition of HAp nanocrystals on the surface via an alternate soaking method.

View Article and Find Full Text PDF

Objective: Inferior pole patellar fractures (IPPFs) pose a significant challenge due to their complex fracture patterns and high risk of complications associated with current treatment methods. This study aims to (1) characterize the fracture patterns of IPPFs using fracture mapping and (2) compare the biomechanical stability and clinical outcomes of treatment with anchor suture with patellar cerclage versus Kirschner-wire tension band combined with patellar cerclage.

Methods: (1) A retrospective analysis was conducted on 61 patients with IPPF.

View Article and Find Full Text PDF

Tibial Plateau Angle Changes following Repair of Salter-Harris Type 1 and 2 Fractures in Dogs.

Vet Comp Orthop Traumatol

January 2025

Veterinary Specialists of Sydney, Sydney, New South Wales, Australia.

Objective:  To determine (1) whether the tibial plateau angle (TPA) in dogs with Salter-Harris type 1 (SH-1) or type 2 (SH-2) fractures of the proximal tibial physis significantly decreases in the time between diagnosis and reevaluation following surgical repair and (2) whether the method of surgical repair influences the change in TPA over time.

Study Design:  This study was a retrospective study. Medical records from 2017 to 2022 were reviewed to identify dogs with SH-1 or SH-2 fractures of the proximal tibial physis that had undergone surgical repair with Kirschner wires (K-wires), with or without a tibial tuberosity tension band.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!