A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis system) with a 13-year mean follow-up. | LitMetric

The authors determined current health status of patients who had been included in a long-term survivorship analysis of a lumbar dynamic stabilizer. Among 133 living patients, 107 (average age at surgery, 44.2 +/- 9.9 years) completed health questionnaires. All patients had initially been scheduled for decompression and fusion for canal stenosis, herniated disc, or both. In 20 patients, the implant was removed, and fusion was performed. The other 87 still had the dynamic stabilizer. Satisfaction, Oswestry disability index, visual analog scales for back and leg pain, short-form (SF-36) quality-of-life physical composite score, physical function, and social function were significantly better (p < or = 0.05) in the patients who still had the dynamic stabilization device. SF-36 scores of the fused subgroup were no worse than those reported elsewhere in patients who had primary pedicle-screw enhanced lumbar fusion. This anatomy-sparing device provided a good 13-year clinical outcome and obviated arthrodesis in 80% of patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10143-009-0199-zDOI Listing

Publication Analysis

Top Keywords

dynamic stabilization
8
stabilization device
8
dynamic stabilizer
8
patients
7
clinical evaluation
4
evaluation lumbar
4
lumbar interspinous
4
dynamic
4
interspinous dynamic
4
device wallis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!