Background: Laparoscopic sleeve gastrectomy (LSG) is gaining popularity as a "per se" bariatric procedure due to its effectiveness on weight loss and comorbidity resolution. The most feared and life-threatening complication after LSG is the staple line leak and its management is still a debated issue. Aim of this paper is to analyze the incidence of leak and the treatment solutions adopted in a consecutive series of 200 LSG.
Methods: From October 2002 to November 2008, 200 patients underwent LSG. Nineteen patients (9.5%) had a body mass index (BMI) of >60 kg/m(2). A 48-Fr bougie is used to obtain an 80-120-ml gastric pouch. An oversewing running suture to reinforce the staple line was performed in the last 100 cases. The technique adopted to reinforce the staple line is a running suture taken through and through the complete stomach wall.
Results: Staple line leaks occurred in six patients (mean BMI 52.5; mean age 41.6 years). Leak presentation was early in three cases (first, second, and third postoperative (PO) day), late in the remaining three cases (11th, 22nd, and 30th PO day). The most common leak location was at the esophagogastric junction (five cases). Mortality was nihil. Nonoperative management (total parenteral nutrition, proton pump inhibitor, and antibiotics) was adopted in all cases. Percutaneous abdominal drainage was placed in five patients. In one case, a small fistula was successfully treated by endoscopic injection of fibrin glue only. Self-expandable covered stent was used in three cases. Complete healing of leaks was obtained in all patients (mean healing time 71 days).
Conclusion: Nonoperative treatment (percutaneous drainage, endoscopy, stent) is feasible, safe, and effective for staple line leaks in patients undergoing LSG; furthermore, it may avoid more mutilating procedures such as total gastrectomy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11695-009-9840-8 | DOI Listing |
J Laparoendosc Adv Surg Tech A
January 2025
Nairobi Bariatric Center, Nairobi, Kenya.
Advancements in surgical stapling devices play a crucial role in improving outcomes for bariatric procedures. This study evaluates the performance and safety of a new endoscopic stapler (EnDrive® Beluga) regarding perioperative results across multiple bariatric surgery types. A retrospective analysis was conducted on 112 patients who underwent bariatric procedures using the Beluga stapler at two centers in the United Arab Emirates and Kenya over a 6-month period (June-December 2023).
View Article and Find Full Text PDFInt J Colorectal Dis
January 2025
Colorectal Surgery Unit, Department of General and Digestive Surgery, Hospital Clínico Universitario de Valencia, Av. Blasco Ibáñez, 17. 46010, Valencia, Spain.
Purpose: This meta-analysis aims to evaluate the efficacy of powered circular staplers (PCS) compared to manual circular staplers (MCS) in reducing anastomotic leakage (AL) and postoperative bleeding (AB) in colorectal surgery.
Methods: Extensive searches were performed in the Embase, PubMed, and SCOPUS electronic bibliographic databases. Most studies were of an observational nature, and only one randomized clinical trial was identified.
Tech Coloproctol
January 2025
Université Laval, 10, De l'Espinay St, Quebec City, QC, G1L 3L5, Canada.
Background: Inadequate bowel perfusion is among risk factors for colorectal anastomotic leaks. Perfusion can be assessed with indocyanine green fluorescence angiography (ICG) during colon resections. Possible benefits from its systematic use in high-risk patients with rectal cancer remain inconsistent.
View Article and Find Full Text PDFBMJ Open Gastroenterol
December 2024
Division of Gastroenterology & Hepatology, Weill Cornell Medicine, New York, New York, USA
Objective: Globally, over 50% of the population is affected by , yet research on its prevalence and impact in patients with obesity undergoing laparoscopic sleeve gastrectomy (LSG) is inconclusive. This study aimed to assess the prevalence of infection in individuals with obesity undergoing LSG, evaluate the percentage of postoperative staple-line leaks, and explore the potential link between infection and staple-line leaks.
Methods: This retrospective analysis assessed adult patients with class III obesity who underwent LSG between 2015 and 2020 at a tertiary care hospital in Riyadh, Saudi Arabia.
Multimed Man Cardiothorac Surg
January 2025
Respiratory Disease Center, Kyoto Katsura Hospital, Kyoto, Japan.
The plane running between two adjacent pulmonary segments consists of a very thin layer of connective tissue through which the pulmonary vein also runs. To perform an anatomically correct segmentectomy, this segmental plane needs to be divided. Before the operation, the locations of vessels and bronchi are confirmed by three-dimensional computed tomography.