A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulmonary nodules: volume repeatability at multidetector CT lung cancer screening. | LitMetric

Purpose: To assess in vivo volumetric repeatability of an automated software algorithm in pulmonary nodules detected during a lung cancer screening trial.

Materials And Methods: This study was approved by an institutional review board. Written informed consent was obtained from all participants. Data were collected from the Multicentric Italian Lung Detection project, a randomized controlled lung cancer screening trial. The first 1236 consecutive baseline computed tomographic (CT) studies performed at the Istituto Nazionale Tumori of Milan were evaluated. Among the enrolled participants, those who underwent repeat low-dose CT after 3 months and had at least one indeterminate nodule with a volume of more than 60 mm(3) (diameter of 4.8 mm or greater) were considered. Nonsolid, part-solid, and pleural-based nodules were excluded from this study. A descriptive analysis was performed by calculating means and standard deviations of nodule volumes at three assessment times (at baseline and 3 and 12 months later). The volume measurement repeatability was determined by using the approach described by Bland and Altman.

Results: One hundred one subjects (70 men, 31 women; mean age, 58 years) with 233 eligible nodules (mean volume, 98.3 mm(3); range, 5-869 mm(3)) were identified. The 95% confidence interval for difference in measured volumes was in the range of +/-27%. About 70% of measurements had a relative difference in nodule volume of less than 10%. No malignant lesions were registered during the follow-up of these subjects.

Conclusion: Semiautomatic volumetry is sufficiently accurate and repeatable and may be useful in assisting with lung nodule management in a lung cancer screening program.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2513081313DOI Listing

Publication Analysis

Top Keywords

lung cancer
16
cancer screening
16
pulmonary nodules
8
nodules volume
8
nodule volume
8
lung
6
volume
5
volume repeatability
4
repeatability multidetector
4
multidetector lung
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!