A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental off-pump transventricular pulmonary valve replacement using a self-expandable valved stent: A new approach for pulmonary incompetence after repaired tetralogy of Fallot? | LitMetric

Objective: Off-pump valve replacement using self-expandable stents is an emerging technique for pulmonary valve disease. However, significant limitations are the lack of easily available valve substitute to be inserted within the stent and, in the setting of repaired tetralogy of Fallot, the existence of huge pulmonary trunk. We report the first experimental results of a transventricular approach using a decellularized porcine xenograft mounted in a self-expandable stent.

Methods: Pulmonary valve replacement was realized in 15 lambs by direct access of the infundibulum through a left thoracotomy, combined with pulmonary artery banding. Animals were followed by transthoracic echocardiography and, after control hemodynamic study, were electively killed either at day 7, month 1, or month 4 after implantation.

Results: Implantation succeeded in all lambs. Two animals died after implantation (1 pneumothorax and 1 endocarditis). Doppler echocardiographic follow-up did not show any significant transvalvular gradient and showed only mild pulmonary regurgitation. The hemodynamic control before termination revealed a systolic pulmonary valve gradient of 18.5 +/- 12.4 mm Hg at 1 week (n = 4), 13.5 +/- 10.6 mm Hg at 1 month (n = 4), and 4.3 +/- 4.9 mm Hg at 4 months (n = 5). Gross examination demonstrated the presence of connective tissue between the valved stent and pulmonary wall, which increased with time.

Conclusion: Fifteen lambs underwent successful deployment of a self-expandable valved stent in the pulmonary position using a transventricular approach. This technique combined with pulmonary artery banding could be a therapeutic option for pulmonary insufficiency after repair of tetralogy of Fallot with a transannular patch.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2008.07.057DOI Listing

Publication Analysis

Top Keywords

pulmonary valve
16
pulmonary
12
valve replacement
12
valved stent
12
replacement self-expandable
8
self-expandable valved
8
repaired tetralogy
8
tetralogy fallot
8
transventricular approach
8
combined pulmonary
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!