An international intercomparison of integrating detectors was conducted at NIRS (National Institute of Radiological Science, Japan) with a 24.4 m(3) inner volume walk-in radon chamber that has systems to control radon concentration, temperature and humidity. During the first intercomparison (05.2007) four groups participated from four countries and for the second intercomparison (10.2007) 17 participants were involved from 11 countries. Most of detectors are in good agreement with each other when compared to the radon level provided by the radon chamber. It appeared that the 70% of detectors are unified within the 20% margin of uncertainty.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2009.03.006DOI Listing

Publication Analysis

Top Keywords

radon chamber
12
radon
6
international intercomparisons
4
intercomparisons integrating
4
integrating radon
4
detectors
4
radon detectors
4
detectors nirs
4
nirs radon
4
chamber international
4

Similar Publications

Association of chronic stress during studies with depressive symptoms 10 years later.

Sci Rep

January 2025

Institute and Clinic for Occupational, Social and Environmental Medicine, LMU University Hospital, LMU Munich, Ziemssenstr. 5, 80336, Munich, Germany.

The long-tern implications of stress during university for individuals' mental health are not well understood so far. Hence, we aimed to examine the potential effect of stress while studying at university on depression in later life. We analysed data from two waves of the longitudinal Study on Occupational Allergy Risks.

View Article and Find Full Text PDF

Estimation radon exposure in underground gold mines in Colombia.

Radiat Prot Dosimetry

December 2024

Radiological Physics Group, Universidad Nacional de Colombia, 65 Avenue 59A St 110, 050034, Medellín, Colombia.

Environmental measurements of Radon and its progeny were carried out in a gold mining area in the department of Antioquia, Colombia. Radon concentration measurements were carried out during 2 y in seven different measurement points in three types of geological zones, by using EPERM electret chambers and DOSEman Pro detectors at each point. Radon concentration values between 858 ± 59 Bq m-3 and 2469 ± 158 Bq m-3 and an equilibrium factor between 0.

View Article and Find Full Text PDF

The uranium mines both developed and abandoned appear to be one of the most significant sources of radon exhalation in the world. Therefore, the study of radon exposure of the population in the areas around rehabilitated uranium mines is very important. This article presents the results of the radon release studies at the rehabilitated Beshtaugorsky uranium mine site, which is now used by local people for hiking and picnicking.

View Article and Find Full Text PDF
Article Synopsis
  • The study assesses radon and thoron exhalation rates using a closed-loop technique with online radon monitors, particularly focusing on the balance of air volume in the sample and detector chambers.
  • An alternative model is proposed that treats the sample and detector chambers as separate entities, refining the mass balance equation to account for air flow rates affecting radon/thoron concentrations.
  • Results indicate that while lower flow rates don't affect long-lived radon buildup, experiments showed that increasing flow rates impacts the effective removal rate of radon, suggesting potential issues with thoron interference at lower flows.
View Article and Find Full Text PDF

Natural radon levels act as markers of hydrodynamic behavior in the mountain karst aquifer of Bossea Cave, Italy.

Sci Rep

November 2024

Department of Environment, Land and Infrastructure Engineering (DIATI), Politecnico di Torino, Turin, Italy.

Article Synopsis
  • - Radon is transported within the Bossea karstic mountain aquifer through both advective and diffusive processes, with fluctuations correlating to hydrodynamics rather than external weather factors.
  • - Delayed concentration peaks of radon in underground water occur after flooding, with a 45-hour delay in the upper canyon and 66 hours in collapse chambers due to varying water flow dynamics.
  • - Different radon levels are detected in the main creek compared to secondary inflows; the main creek experiences increases during flooding, while secondary inflows see dilution from new infiltrating water, with no significant relationship found between radon emissions and seismic activity.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!